Related Experiment Video
Updated: Sep 25, 2025

A Novel Inhalation Mask System to Deliver High Concentrations of Nitric Oxide Gas in Spontaneously Breathing Subjects
Published on: May 4, 2021
The Aerosol-Generating Effect Among Noninvasive Positive Pressure Ventilation, High-Flow Nasal Cannula, Nonrebreather
Tzu-Yao Hung1, Wei-Lun Chen2, Yung-Cheng Su3
1Department of Emergency Medicine, Zhong-Xing branch, Taipei City Hospital, Taipei City, Taiwan; Faculty of Medicine, National Yang Ming Chiao Tung University, Taipei City, Taiwan; School of Medicine, College of Medicine, Fu Jen Catholic University, New Taipei, Taiwan; CrazyatLAB (Critical Airway Training Laboratory), Taipei City, Taiwan.
Study Objective:
To evaluate aerosol dispersion and exposure risk during oxygenation therapy among health care personnel.
Methods:
This study compared the aerosol dispersion effect produced through continuous positive airway pressure (CPAP), bilevel positive airway pressure (BiPAP), BiPAP with face coverings, a high-flow nasal cannula (HFNC) with face coverings, nasal cannula oxygenation (NCO) at 15 L/min with face coverings, nonrebreather mask (NRM), and ventilator-assisted preoxygenation (VAPOX) during oxygenation therapy at a minute ventilation of 10 L/min and 20 L/min. The length and width of aerosol dispersion were recorded, and aerosol concentrations were then detected at a mannequin's head, trunk, and feet.
Results:
The average length dispersion distance of CPAP was 47.12 cm (SD, 12.56 cm), of BiPAP was 100.13 cm (SD, 6.03 cm), of BiPAP with face coverings was 62.20 cm (SD, 8.46 cm), of HFNC with face coverings was 67.09 cm (SD, 12.74 cm); of NCO with face coverings was 85.55 cm (SD, 7.28 cm); and of NRM was 63.08 cm (SD, 15.33 cm); VAPOX showed no visible dispersion. The aerosol concentrations at the feet under CPAP and at the head under BiPAP were significantly higher than those observed without an oxygen device. Compared with no oxygen device, the aerosol concentration with HFNC was higher at the mannequin's head, trunk, and feet; whereas it was lower with VAPOX and NRM. Moreover, when translated to the number of virus particles required to infect medical personnel (Nf), VAPOX took more time to achieve Nf than other devices.
Conclusion:
Strong flow from the oxygenation devices resulted in increased aerosol concentrations. CPAP at the feet side, BiPAP at the head side, HFNC, and NCO with face coverings significantly increase aerosol exposure and should be used with caution. Aerosol concentrations at all positions were lower with NRM and VAPOX.
More Related Videos
05:43Topical Airway Anesthesia for Awake-endoscopic Intubation Using the Spray-as-you-go Technique with High Oxygen Flow
Published on: January 13, 2017
09:36Halogenated Agent Delivery in Porcine Model of Acute Respiratory Distress Syndrome via an Intensive Care Unit Type Device
Published on: September 24, 2020
Related Concept Videos
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Ventilatory Modes
There are three ventilatory modes: full support, partial support, and spontaneous. These are described below.
Full Support Modes
Full support modes include controlled mechanical ventilation, continuous mandatory...
Administering Oxygen by Nasal Cannula
Nasal Cannulas
A nasal cannula is a lightweight tube split into two prongs placed in the nostrils,...
Mechanical Ventilation I: Indication and Settings