Extraction Induced by Emulsion Breaking for Ca, Cu, Fe, Mn, Ni, and Zn Determination in Chocolate by Flame Atomic
Dilek Bakircioglu1, Yasemin Bakircioglu Kurtulus1, Nukte Topraksever1
1Trakya University, Faculty of Science, Department of Chemistry, Edirne, Turkey.
Background:
Chocolate is a rich source of essential and non-essential elements. A new liquid-liquid extraction (LLE) approach, extraction induced by emulsion breaking (EIEB), is proposed in which the analyzed elements are transferred from the organic phase to the aqueous phase before measurement by flame atomic absorption spectrometry (FAAS).
Objective:
To compare EIEB to microwave digestion (MWD) for extraction of elements from chocolate prior to FAAS.
Methods:
EIEB parameters were varied to optimize the procedure. EIEB-FAAS was then compared to MWD-FAAS for the analysis of Ca, Cu, Fe, Mn, Ni, and Zn in milk and dark chocolate samples. A certified reference material (NIST 2384, baking chocolate) was analyzed to determine the recoveries of Ca, Cu, Fe, Mn, and Zn by the two methods.
Results:
The optimized EIEB extraction method involves dilution of tempered chocolate with toluene, ultrasonic emulsification with acidified Triton X-114, breaking the emulsion by heating, and centrifugation to produce two well-defined phases. Analysis of dark and milk chocolate samples showed similar repeatability by EIEB-FAAS (RSDr 0.3 to 6.6% in dark and 0.5 to 8.7% in milk) and MWD-FAAS (RSDr 0.5 to 5.4% in dark and 0.7 to 10.2% in milk), with no significant difference detected between the methods for analysis of Ca, Cu, Fe, Mn, Ni, and Zn based on Student's t-test. Analysis of NIST 2384 baking chocolate certified reference material for Ca, Cu, Fe, Mn, and Zn demonstrated recoveries of 98.6 to 99.5% for EIEB-FAAS compared to 95.8 to 98.6% for MWD-FAAS.
Conclusion:
EIEB-FAAS was shown to provide high recovery and excellent repeatability for accurate determination of Ca, Cu, Fe, Mn, Ni, and Zn from dark and milk chocolates.
Highlight:
The EIEB-FAAS method is simpler and requires fewer reagents compared to other sample preparation methods and allows the calibration to be carried out using aqueous calibration solutions.
More Related Videos
08:55Methods of Ex Situ and In Situ Investigations of Structural Transformations: The Case of Crystallization of Metallic Glasses
Published on: June 7, 2018
09:42Fabrication of a Dipole-assisted Solid Phase Extraction Microchip for Trace Metal Analysis in Water Samples
Published on: August 7, 2016
Related Concept Videos
Atomic Absorption Spectroscopy: Atomization Methods
Extraction: Advanced Methods
Atomic Absorption Spectroscopy: Lab
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing...
Qualitative Analysis
For instance, group IV...
Atomic Fluorescence Spectroscopy
Sample Preparation for Analysis: Advanced Techniques
Acid digestion with strong acids is commonly used to dissolve inorganic materials that are insoluble (do not dissolve) in water. This method can be useful for...