Signal Acquisition, Score Interpretation, and Economics of a Non-Invasive Point-of-Care Test for Coronary Artery Disease
Published on: August 9, 2024
Signal Quality Assessment of Compressively Sensed Electrocardiogram
Objective:
Develop a signal quality index (SQI) to determine the quality of compressively sensed electrocardiogram (ECG) by estimating the signal-to-noise ratio (SNR).
Methods:
The SQI used random forests, with the ratio of the standard deviations of an ECG segment and a clean ECG and the Wasserstein metric between the amplitude distributions of an ECG segment and a clean ECG, as features. The SQI was tested using the Long-Term Atrial Fibrillation Database (LTAFDB) and the PhysioNet/CinC Challenge 2011 Database Set A (CinCDB). Clean ECG segments from the LTAFDB were corrupted using simulated motion artifact, with preset SNR between -12 dB and 12 dB. The CinCDB was used as-it-is. The databases were compressively sensed using three types of sensing matrices at three compression ratios (50%, 75%, and 95%). For LTAFDB, the RMSE and Spearman correlation between the SQI and the preset SNR were used for evaluation, while for CinCDB, accuracy and F1 score were used.
Results:
The average RMSE was 3.18 dB and 3.47 dB in normal and abnormal ECG. The average Spearman correlation was 0.94 and 0.93 in normal and abnormal ECG, respectively. The average accuracy and F1 score were 0.90 and 0.88, respectively.
Conclusion:
The SQI determined the quality of compressively sensed ECG and generalized across different databases. There was no consequential effect on the SQI due to abnormal ECG or compression using different sensing matrices and compression ratios.
Significance:
Without reconstruction, the SQI can inform which ECG should be analyzed to reduce false alarms due to contamination.
Related Concept Videos
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and...
Correlation between ECG and Cardiac Cycle
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...
ECG Interpretation of Rhythms
Components of the Electrocardiogram
The primary components of a normal ECG waveform in Normal sinus rhythm(NSR) include the P wave, PR interval, QRS complex, ST segment, T wave, and occasionally a U wave.
ECG waveforms are divided by vertical and horizontal lines at standard intervals.
The horizontal axis measures time and rate, and the vertical axis measures amplitude or voltage....
Pulse amplitude and quality
A weak or absent pulse may indicate reduced cardiac output or poor left ventricular contraction, which can be signs of cardiovascular dysfunction or...
Electrocardiogram Fundamentals
An electrocardiogram (ECG) is a diagnostic tool for identifying cardiac conditions such as arrhythmias, conduction abnormalities, and myocardial ischemia.
Definition
An electrocardiogram (ECG) visualizes the heart's electrical activity by tracing the electrical movement associated with each heartbeat on a graph or monitor. As the heart beats, an electrical wave passes through it, correlating with the cardiac cycle events.
Parts of an ECG
An ECG utilizes electrodes on the skin...
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion,...