Related Experiment Video
Updated: Sep 25, 2025

Single Cell Fate Mapping in Zebrafish
Published on: October 5, 2011
Biosensor for deconvolution of individual cell fate in response to ion beam irradiation
Martin Niklas1,2, Julian Schlegel1,2, Hans Liew1,2
1Division of Molecular and Translational Radiation Oncology and Clinical Cooperation Unit Translational Radiation Oncology, German Cancer Research Center (DKFZ) and Heidelberg University Hospital, 69120 Heidelberg, Germany.
Abstract:
Clonogenic survival assay constitutes the gold standard method for quantifying radiobiological effects. However, it neglects cellular radiation response variability and heterogeneous energy deposition by ion beams on the microscopic scale. We introduce "Cell-Fit-HD4D" a biosensor that enables a deconvolution of individual cell fate in response to the microscopic energy deposition as visualized by optical microscopy. Cell-Fit-HD4D enables single-cell dosimetry in clinically relevant complex radiation fields by correlating microscopic beam parameters with biological endpoints. Decrypting the ion beam's energy deposition and molecular effects at the single-cell level has the potential to improve our understanding of radiobiological dose concepts as well as radiobiological study approaches in general.
More Related Videos
09:48Discrimination and Characterization of Heterocellular Populations Using Quantitative Imaging Techniques
Published on: June 30, 2017
08:56Simultaneous Imaging and Flow-Cytometry-based Detection of Multiple Fluorescent Senescence Markers in Therapy-Induced Senescent Cancer Cells
Published on: July 12, 2022