Microstructure, mechanical properties and osseointegration ability of Ta-20Zr alloy used as dental implant material
Related Experiment Video
Updated: Sep 25, 2025

An Improved Mechanical Testing Method to Assess Bone-implant Anchorage
Published on: February 10, 2014
Pinghua Ou1,2, Taomei Zhang2, Jianying Wang2
1Department of Stomatology, The Third Xiangya Hospital, Central South University, Changsha, Hunan, 410013, People's Republic of China.
Abstract:
The aim of this study was to evaluate the application prospect of a tantalum (Ta) and zirconium (Zr) alloy as a dental implant material. The Ta-20Zr (wt.%) alloy was prepared by powder metallurgy, and its microstructure and mechanical properties were analyzed by standard techniques. The effect of Ta-20Zr alloy on inflammation, bone remodeling and osseointegration was analyzed in rat and rabbit models by biochemical, histological and imaging tests. The Ta-20Zr alloy showed excellent mechanical compatibility with the bone tissue on account of similar elastic modulus (49.2 GPa), thereby avoiding the 'stress shielding effect'. Furthermore, Ta-20Zr alloy enhanced the inflammatory response by promoting secretion of interleukin-6 (IL-6) and IL-10, and facilitated the balance between the M1/M2 macrophage phenotypes. Finally, Ta-20Zr also showed excellent osseointegration and osteogenic ability without any systemic side effects, making it an ideal dental implant material.