Abstract:
Cyanide is a poison widely used in cases of suicide or homicide. Although various methods to identify and quantify this substance are reported in the literature, they are mainly validated on biological fluids (e.g., blood and urine). In the present study, the Anion-Exchange Liquid Chromatography with Pulsed Amperometric Detection (IC-PAD) method was validated on blood and, for the first time, on gastric content, and organs (brain, lung, and liver). For each matrix, linearity, accuracy, precision, limit of detection (LOD), lower limit of quantification (LLOQ), matrix interferences, and carryover were assessed. The samples were extracted by steam distillation in acid environment for the following analysis by IC-PAD. Furthermore, cyanide values found in two real poisoning cases are reported. For each investigated matrix, the analytical method satisfied all acceptance criteria for validation: it showed a good precision and accuracy, selectivity, and sensitivity with no carryover and matrix interference. The extraction by steam distillation in acid environment REDUCED the interference of the matrices and ALLOWED to perform the analysis with good precision and accuracy. In case #1, analysis showed a blood cyanide concentration of 0.99 μg/ml. In case #2, cyanide concentrations were 1.3 μg/g in brain, 0.8 μg/g in lung, 1.6 μg/g in liver, and 1.2 μg/g in gastric content. The cyanide concentrations found in the two reported cases have been suitable to cause death by poisoning.
More Related Videos
08:51Intra-cardiac Side-Firing Light Catheter for Monitoring Cellular Metabolism using Transmural Absorbance Spectroscopy of Perfused Mammalian Hearts
Published on: May 12, 2019
13:35A Convenient Method for Extraction and Analysis with High-Pressure Liquid Chromatography of Catecholamine Neurotransmitters and Their Metabolites
Published on: March 1, 2018
Related Concept Videos
High-Performance Liquid Chromatography: Types of Detectors
Determining the pH of Salt Solutions
Gas Chromatography: Types of Detectors-II
Precipitation Titration: Endpoint Detection Methods
In the Volhard method, a standard excess of AgNO3 is first added to the...
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...