Related Experiment Video
Updated: Sep 25, 2025

Ultrasensitive Detection of Biomarkers by Using a Molecular Imprinting Based Capacitive Biosensor
Published on: February 16, 2018
Development of an Ultrasmall and Biocompatible Platinum Nanozyme Encapsulated by Zwitterionic Dendrimer for Highly
Yanshuai Cui1,2, Kai Liu3, Tianming Cui3
1State Key Laboratory of Metastable Materials Science and Technology, College of Materials Science and Engineering, Yanshan University, Qinhuangdao 066004, China.
Abstract:
Many kinds of noble metal nanoparticles can mimic the peroxidase-like function of horseradish peroxidase, which results in their wide applications in bio-related detection and drug delivery. However, those metal nanoparticles usually have low stability and reduced catalytic activity in biological complex medium. Herein, a zwitterionic peroxidase-like enzyme has been developed, which has high stability in fibrinogen solutions and high sensitivity for glucose detection. Maleic anhydride, cysteamine, and zwitterionic peptide EKEKC (EK-5) were used to modify generation 5 poly(amido amine) dendrimers (G5 PAMAM) to prepare zwitterionic dendrimer G5MEKnC with nonfouling properties. Finally, the G5MEKnC-encapsulated platinum nanoparticles (Pt-G5MEK50C) were prepared by entrapping the platinum nanoparticles (1.40 nm) in the catalytic centers in the interior of G5MEK50C. Pt55-G5MEK50C showed high stability in the buffer solution and the fibrinogen solution within 4 days. They also displayed high biocompatibility toward HeLa cells based on cytotoxicity results and morphological observations. Furthermore, the catalytic oxidation of 3,3',5,5'-tetramethylbenzidine with H2O2 by Pt55-G5MEK50C followed the Michaelis-Menten equation, which confirmed their peroxidase-like properties. The catalytic mechanism was due to the generation of •OH from H2O2. More importantly, the peroxidase-like ability of Pt55-G5MEK50C was successfully used to establish a method for the determination of glucose concentration with a broad linear range of 1-2000 μM and a low detection limit of 0.1 μM. This method was highly accurate for the determination of glucose concentration in plasma. The zwitterionic dendrimer template enhanced the properties of Pt55-G5MEK50C. Taken together, a new kind of biocompatible nanozyme has been developed and successfully used for the sensitive detection of glucose in bio-related medium.
More Related Videos
13:42Dry Film Photoresist-based Electrochemical Microfluidic Biosensor Platform: Device Fabrication, On-chip Assay Preparation, and System Operation
Published on: September 19, 2017
04:33Author Spotlight: Engineering Molecular Tools for Disease Detection and Imaging
Published on: December 8, 2023