Related Experiment Video
Updated: Sep 25, 2025

Gas Chromatography-Mass Spectrometry Paired with Total Vaporization Solid-Phase Microextraction as a Forensic Tool
Published on: May 25, 2021
Oleamide as analyte protectant in GC analysis of THC and its metabolites in blood
Andrzej L Dawidowicz1, Michal P Dybowski1, Michal Rombel1
1Department of Chromatography, Institute of Chemical Sciences, Faculty of Chemistry, Maria Curie Sklodowska University, 20-031 Lublin, Poland.
Abstract:
Methods for the analysis of cannabinoids in bio-matrices are continually being developed, to achieve a proper sensitivity required for their detection and accuracy in their quantification. The presented paper shows that the analytical sensitivity of GC-MS to THC and its metabolites in blood samples can be significantly increase by oleamide (OLA) addition to the examined sample, which evokes the matrix effect of transient character. The magnitude of signal increment resulting from oleamide presence in the examined sample is the greatest for THC metabolites and depends on oleamide concentration in the examined sample. The use of transient matrix effect to increase the sensitivity of the analysis can be applied not only in QuEChERS procedure, which is applied in the described experiments, but also in other blood sample preparation methods. Evoking the transient matrix effect by means of OLA in the experimental analytical quantitation of THC and its metabolites in blood allowed to lower limit of detection (LOD) approximately by 20.5%, 87.6% and 90.1% in the case of THC, THC-OH and THC-COOH, respectively.
More Related Videos
10:13Author Spotlight: An Efficient Methodology to Confidently Differentiate and Characterize Fentanyl Analogs
Published on: November 8, 2024
10:17High-throughput and Comprehensive Drug Surveillance Using Multisegment Injection-Capillary Electrophoresis-Mass Spectrometry
Published on: April 23, 2019
Related Concept Videos
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
High-Performance Liquid Chromatography: Types of Detectors
Gas Chromatography: Types of Detectors-II
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...