Pulse perfusion index for predicting intrapartum fever during epidural analgesia
Caixia Sun1, Shujun Ren1, Chen Chen1
1Department of Anesthesiology, Affiliated People's Hospital of Jiangsu University, Zhenjiang City, Jiangsu Province 212002, China.
Study Objective:
To assess whether pulse perfusion index (PI) values could be employed to predict intrapartum fever and to provide a cut-off PI value for predicting intrapartum fever occurrence.
Design:
We conducted a single-center, prospective, observational study.
Setting:
Delivery room at the Department of Obstetrics, Affiliated Hospital of Jiangsu University.
Patients:
117 parturients who intended to have a vaginal delivery.
Interventions:
Each parturient received epidural analgesia.
Measurements:
We checked each parturient's tympanic temperature before analgesia (T0), at 1 h (T1) and 2 h (T2) after analgesia, immediately at the end of the second (T3) and third (T4) stages of labor, and at 1 h postpartum (T5). A temperature of ≥38°C was defined as fever. PI, measured on the right second toe, was recorded before analgesia (PI0) and at 10 min (PI10), 20 min (PI20), and 30 min (PI30) after analgesia. The PI change rate was calculated as the incremental change in PI30 from PI0, divided by the PI0. Receiver operating characteristic (ROC) curves were used to verify the utility of the PI30 and PI change rate values for predicting intrapartum fever.
Main Results:
We found that peak temperature (TP) occurred at the end of the second or the third stage of labor. Within 30 min after analgesia, the PI showed a significant increase over time and there was a linear correlation between PI30 and TP values (P < 0.001, r = 0.544). The PI10, PI20, PI30 and PI change rate in febrile parturients were higher than those in afebrile parturients (P < 0.001). The area under the ROC (AUROC) for PI30 was 0.818 (P < 0.001) with a cut-off of 9.30. The AUROC of the PI change rate was 0.738 (P < 0.001) with a cut-off of 3.45.
Conclusions:
PI30 and PI change rate values could be used to predict intrapartum fever in parturients after epidural analgesia.
More Related Videos
08:08Determination of the Transport Rate of Xenobiotics and Nanomaterials Across the Placenta using the ex vivo Human Placental Perfusion Model
Published on: June 18, 2013
07:51Standardized Hemorrhagic Shock Induction Guided by Cerebral Oximetry and Extended Hemodynamic Monitoring in Pigs
Published on: May 21, 2019
Related Concept Videos
Local Anesthetics: Clinical Application as Epidural Anesthesia
Since epidural anesthetics can be infused through an epidural catheter, all types of drugs, including short-acting ones, can be administered. Chloroprocaine and lidocaine are examples of short and long-duration anesthetics, respectively. Bupivacaine...
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...