Performance of Wide-Angle Tomosynthesis with Synthetic Mammography in Comparison to Full Field Digital Mammography
Sadia Khanani1, Carrie Hruska1, Agnes Lazar2
1Department of Radiology, Mayo Clinic, 200 First street SW, Rochester, MN 55905.
Rationale And Objectives:
The purpose of this study was to test for superiority of wide-angle digital breast tomosynthesis plus synthetic mammography (Insight 2D) in comparison to full-field digital mammography (FFDM).
Materials And Methods:
In this study, twenty readers interpreted 350 screening and diagnostic cases of wide-angle digital breast tomosynthesis (DBT) plus Insight 2D and FFDM in two separate reading sessions separated by at least a 6-week washout period. Breast-level estimates of the area under the curve and sensitivity along with subject-level recall rate were measured and compared between wide-angle DBT plus Insight 2D and FFDM. The same measures were also assessed for dense breasts. A hierarchical analysis plan was used to control the study's type I error rate at 0.05.
Results:
The mean breast-level area under the curve for distinguishing breasts with cancer from non-cancer breasts was 0.893 with DBT plus Insight 2D versus 0.837 with FFDM, showing superiority of DBT plus Insight 2D (p < 0.001). Breast-level sensitivity was significantly superior for DBT plus Insight 2D in comparison to FFDM (0.852 vs. 0.805, p = 0.043). Subject-level recall rate for DBT plus Insight 2D was significantly lower in comparison to FFDM (0.344 vs. 0.473, p < 0.001). For dense breasts, the readers' accuracy with DBT plus Insight 2D was superior to their accuracy with FFDM (0.875 vs. 0.830, p = 0.026), and their recall rate was significantly lower for DBT plus Insight 2D in comparison to FFDM (0.338 vs. 0.441, p = 0.003).
Conclusion:
Reader performance with wide-angle DBT plus Insight 2D is superior to that with FFDM, showing significantly higher breast-level accuracy and sensitivity and significantly lower recall rates.
More Related Videos
15:48Tracking the Mammary Architectural Features and Detecting Breast Cancer with Magnetic Resonance Diffusion Tensor Imaging
Published on: December 15, 2014
08:46Using Synchrotron Radiation Microtomography to Investigate Multi-scale Three-dimensional Microelectronic Packages
Published on: April 13, 2016
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography