Related Experiment Video
Updated: Aug 4, 2026

Automated Joint Space Detection Improves Bone Segmentation Accuracy
Published on: November 28, 2025
Ultrasound image denoising using generative adversarial networks with residual dense connectivity and weighted joint
Lun Zhang1,2, Junhua Zhang1
1School of Information Science and Engineering, Yunnan University, Kunming, Yunnan, China.
Background:
Ultrasound imaging has been recognized as a powerful tool in clinical diagnosis. Nonetheless, the presence of speckle noise degrades the signal-to-noise of ultrasound images. Various denoising algorithms cannot fully reduce speckle noise and retain image features well for ultrasound imaging. The application of deep learning in ultrasound image denoising has attracted more and more attention in recent years.
Methods:
In the article, we propose a generative adversarial network with residual dense connectivity and weighted joint loss (GAN-RW) to avoid the limitations of traditional image denoising algorithms and surpass the most advanced performance of ultrasound image denoising. The denoising network is based on U-Net architecture which includes four encoder and four decoder modules. Each of the encoder and decoder modules is replaced with residual dense connectivity and BN to remove speckle noise. The discriminator network applies a series of convolutional layers to identify differences between the translated images and the desired modality. In the training processes, we introduce a joint loss function consisting of a weighted sum of the L1 loss function, binary cross-entropy with a logit loss function and perceptual loss function.
Results:
We split the experiments into two parts. First, experiments were performed on Berkeley segmentation (BSD68) datasets corrupted by a simulated speckle. Compared with the eight existing denoising algorithms, the GAN-RW achieved the most advanced despeckling performance in terms of the peak signal-to-noise ratio (PSNR), structural similarity (SSIM), and subjective visual effect. When the noise level was 15, the average value of the GAN-RW increased by approximately 3.58% and 1.23% for PSNR and SSIM, respectively. When the noise level was 25, the average value of the GAN-RW increased by approximately 3.08% and 1.84% for PSNR and SSIM, respectively. When the noise level was 50, the average value of the GAN-RW increased by approximately 1.32% and 1.98% for PSNR and SSIM, respectively. Secondly, experiments were performed on the ultrasound images of lymph nodes, the foetal head, and the brachial plexus. The proposed method shows higher subjective visual effect when verifying on the ultrasound images. In the end, through statistical analysis, the GAN-RW achieved the highest mean rank in the Friedman test.
Related Concept Videos
Residuals and Least-Squares Property
If the observed data point lies above the line, the residual is positive, and the line underestimates the actual data value for y. If the observed data point lies below the line, the residual is negative, and the line overestimates the actual data value for y.
The process of fitting the best-fit...
Ultrasonography
During an ultrasonography procedure, a handheld device called...
Dense Connective Tissue
Dense Regular Connective Tissue
In dense regular connective tissue, fibers are arranged parallel to each other, enhancing its tensile strength and resistance to stretching in the direction of the fiber orientations. Ligaments and tendons are made of dense regular...
Reducing Line Loss
With a step-up transformer at the source, the voltage is increased, thereby reducing the current in the transmission lines since power loss...
Deconvolution
Deconvolution involves several mathematical techniques to derive the impulse response. One common approach is polynomial division. In this method, the input and output sequences are treated as coefficients of...