Optimizing daylight utilization of flat skylights in heritage buildings
Mohamed Marzouk1, Maryam ElSharkawy2, Ayman Mahmoud3
1Professor of Construction Engineering and Management, Structural Engineering Department, Faculty of Engineering, Cairo University, 12613 Giza, Egypt.
Introduction:
Adapted reuse in old historical buildings has been a real challenge since the state of deterioration is usually found severe, and suggested retrofitting is applied with high delicacy to preserve the building originality. Additionally, on altering the potential users' activity, special considerations are required to fulfill the new needs. Daylight in historical buildings has a special significance in conceiving the massive artistic content within the interior spaces, in providing visual comfort for users, and affecting the total energy performance.
Objectives:
The main goal is to meet the new daylight requirements in heritage building spaces, and to rely on relaxing daylight instead of artificial light sources during the day.
Methods:
The research is implemented in Tosson Palace, a historical palace in Egypt, where a top-lit space's daylight performance is assessed using Rhino + Grasshopper's Diva package, then the skylight is parametrically configured to optimize daylighting conditions using Radiance, and Daysim engines in high intensity solar climate. Optimization of skylight glazing technologies and skylight size is conducted by changing optimization parameters including the number the two perpendicular mullions grid, and mullions' depth, which also acts as a shading element. These parameters are genetically optimized using a multi-objective octopus plugin and the optimized configuration is evaluated using LEED v4.1 in Spatial Daylight Autonomy (sDA), and Annual Sun Exposure (ASE) criteria that show both the daylight adequacy, and the comfortable daylight exposure percentages in the skylight covered space.
Results:
The outcomes offer guidance for heritage adapted reuse in hot climatic conditions with minimum design interventions to meet the original design and provide potential users' comfort conditions. Furthermore, enhancement of both visual, and thermal conditions through the skylight configurations is to be studied.
Conclusion:
The selected optimum case succeeded in compromising the assessing metrics such that ASE was reduced by 38% from the base-case, avoiding unpleasant direct daylight, and providing protection for interior artifacts from sunlight and achieving a moderate uniform daylight distribution on both affected floors levels.
Related Concept Videos
Design Example: Sustainability in Concrete Building
There are multiple approaches to achieve sustainability in a commercial concrete building. For instance, construct a concrete parking area under the building, utilizing pervious concrete paver blocks in open areas to facilitate rainwater collection through an underground...
Masonry Curtain Walls
Cavity Drainage and Flashings in Masonry walls
Weep holes, strategically placed at the base of the cavity, are critical for draining accumulated water. These openings are created by leaving head...
Masonry Cavity Walls
Maintaining a clean cavity during construction...
Thermal Insulation in Masonry Walls
External insulation can be applied using an Exterior Insulation and Finish System (EIFS), which involves affixing panels of plastic foam to the wall and covering them with a polymeric stucco reinforced with glass fiber mesh....
Spanning Openings in Brick Walls
Lintels are primary supports used to span openings and can be crafted from materials such as reinforced concrete, steel-reinforced brick masonry, or simple steel angles. These are straightforward to install and are typically concealed...