Related Experiment Video
Updated: Sep 24, 2025

Measuring the Carotid to Femoral Pulse Wave Velocity Cf-PWV to Evaluate Arterial Stiffness
Published on: May 3, 2018
Consumer Devices for Patient-Generated Health Data Using Blood Pressure Monitors for Managing Hypertension:
Jonathan R Treadwell1, Benjamin Rouse1, James Reston1
1ECRI, Plymouth Meeting, PA, United States.
Background:
In the era of digital health information technology, there has been a proliferation of devices that collect patient-generated health data (PGHD), including consumer blood pressure (BP) monitors. Despite their widespread use, it remains unclear whether such devices can improve health outcomes.
Objective:
We performed a systematic review of the literature on consumer BP monitors that collect PGHD for managing hypertension to summarize their clinical impact on health and surrogate outcomes. We focused particularly on studies designed to measure the specific effect of using a BP monitor independent of cointerventions. We have also summarized the process and consumer experience outcomes.
Methods:
An information specialist searched PubMed, MEDLINE, and Embase for controlled studies on consumer BP monitors published up to May 12, 2020. We assessed the risk of bias using an adapted 9-item appraisal tool and performed a narrative synthesis of the results.
Results:
We identified 41 different types of BP monitors used in 49 studies included for review. Device engineers judged that 38 (92%) of those devices were similar to the currently available consumer BP monitors. The median sample size was 222 (IQR 101-416) participants, and the median length of follow-up was 6 (IQR 3-12) months. Of the included studies, 18 (36%) were designed to isolate the clinical effects of BP monitors; 6 of the 18 (33%) studies evaluated health outcomes (eg, mortality, hospitalizations, and quality of life), and data on those outcomes were unclear. The lack of clarity was due to low event rates, short follow-up duration, and risk of bias. All 18 studies that isolated the effect of BP monitors measured both systolic and diastolic BP and generally demonstrated a decrease of 2 to 4 mm Hg in systolic BP and 1 to 3 mm Hg in diastolic BP compared with non-BP monitor groups. Adherence to using consumer BP monitors ranged from 38% to 89%, and ease of use and satisfaction ratings were generally high. Adverse events were infrequent, but there were a few technical problems with devices (eg, incorrect device alerts).
Conclusions:
Overall, BP monitors offer small benefits in terms of BP reduction; however, the health impact of these devices continues to remain unclear. Future studies are needed to examine the effectiveness of BP monitors that transmit data to health care providers. Additional data from implementation studies may help determine which components are critical for sustained BP improvement, which in turn may improve prescription decisions by clinicians and coverage decisions by policy makers.
Related Concept Videos
Errors occurring during blood pressure monitoring
Several factors...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Pre-Procedural Guidelines for Assessing Blood Pressure
Hypertension III: Clinical Manifestations and Diagnostic Studies
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.