Stainless steel electrochemical capacitive microneedle sensors for multiplexed simultaneous measurement of pH, nitrates, and phosphates
Related Experiment Video
Updated: Sep 24, 2025

Hollow Microneedle-based Sensor for Multiplexed Transdermal Electrochemical Sensing
Published on: June 1, 2012
Samuel M Mugo1, Weihao Lu2, Stephane Lemieux3
1Physical Sciences Department, MacEwan University, 10700-104 Avenue, Edmonton, AB, T5J 4S2, Canada. mugos@macewan.ca.
Abstract:
Concerns for agri-food safety and environmental management require development of simple to use and cost- and time-effective multiplex sensors for point-of-need (PON) chemical analytics by public end-user. Simultaneous detection of nitrates, phosphates, and pH is of importance in soil and water analysis, agriculture, and food quality assessment. This article demonstrates a suite of stainless steel microneedle electrochemical sensors for multiplexed measurement of pH, nitrate, and phosphate using faradaic capacitance derived from cyclic voltammetry as the mode of detection. The multi-target microneedle sensors were fabricated by layer-by-layer (LbL) assembly in a stainless steel hypodermic microneedle substrate. For nitrate sensing, the stainless steel was coated with carbon nanotube/cellulose nanocrystal (CNT)/CNC) decorated with silver nanoparticles (Ag). For pH measurement, the polyaniline (pANI) was coated onto the CNT/CNC@Ag film, while for phosphate detection, the CNT/CNC/Ag @pANI microneedle was further decorated with ammonium molybdenum tetrahydrate (AMT). The microelectrode platforms were characterized by FTIR, Raman, and microscopic techniques. The nitrate- and phosphate-based microneedle electrochemical sensors had excellent selectivity and sensitivity, with a determined limit of detection (LOD) of 0.008 mM and 0.007 mM, respectively. The pH microneedle sensor was responsive to pH in the linear range of 3-10. The three microneedle sensors yielded repeatable results, with a precision ranging from 4.0 to 7.5% RSD over the concentration ranges tested. The inexpensive (~ 1 $ CAD) microneedle sensors were successfully verified for use in quantification of nitrate, pH, and phosphate in brewed black coffee as a real sample. As such, the microneedle sensors are economical devices and show great promise as robust platforms for PON precision chemical analytics.
More Related Videos
08:22Ultrasensitive Detection of Biomarkers by Using a Molecular Imprinting Based Capacitive Biosensor
Published on: February 16, 2018
08:15Fabrication of Fine Electrodes on the Tip of Hypodermic Needle Using Photoresist Spray Coating and Flexible Photomask for Biomedical Applications
Published on: November 28, 2017