Continuous Glucose Monitoring Profiles in Healthy, Nondiabetic Young Children
Stephanie N DuBose1, Lauren G Kanapka1, Brenda Bradfield2
1Jaeb Center for Health Research, Tampa, Florida 33647, USA.
Insights
This study establishes normal continuous glucose monitoring (CGM) ranges for healthy young children. These findings provide essential benchmarks for pediatric diabetes research and clinical practice.
Area of Science:
- Pediatric Endocrinology
- Metabolic Research
- Biomedical Engineering
Background:
- Continuous glucose monitoring (CGM) is vital for diabetes management and research.
- Existing CGM data primarily focuses on adults and older children, leaving a gap for very young, nondiabetic children.
Purpose of the Study:
- To establish normative sensor glucose ranges in healthy, nondiabetic children aged 1 to 6 years.
- To utilize a current-generation CGM sensor for data collection.
Main Methods:
- Prospective observational study involving 39 healthy, nondiabetic children (1-6 years) with normal BMI.
- Utilized a blinded Dexcom G6 Pro CGM device worn for approximately 10 days per participant.
- Analyzed CGM metrics including mean glucose, hyperglycemia, hypoglycemia, and glycemic variability.
Main Results:
- Mean average glucose was 103 mg/dL (5.7 mmol/L).
- Median time within the 70-140 mg/dL range was 96%.
- Median time with glucose <70 mg/dL was 0.4% (6 min/day), and >140 mg/dL was 3.4% (49 min/day).
Conclusions:
- This study successfully collected normative CGM data for young children, addressing a critical knowledge gap.
- The established glycemic measures serve as a valuable benchmark for future pediatric clinical studies.
- Findings support the use of CGM in pediatric research and clinical settings.
Context:
Continuous glucose monitoring (CGM) is increasingly being used both for day-to-day management in patients with diabetes and in clinical research. While data on glycemic profiles of healthy, nondiabetic individuals exist, data on nondiabetic very young children are lacking.
Objective:
This work aimed to establish reference sensor glucose ranges in healthy, nondiabetic young children, using a current-generation CGM sensor.
Methods:
This prospective observational study took place in an institutional practice with healthy, nondiabetic children aged 1 to 6 years with normal body mass index. A blinded Dexcom G6 Pro CGM was worn for approximately 10 days by each participant. Main outcome measures included CGM metrics of mean glucose, hyperglycemia, hypoglycemia, and glycemic variability.
Results:
Thirty-nine participants were included in the analyses. Mean average glucose was 103 mg/dL (5.7 mmol/L). Median percentage time between 70 and 140 mg/dL (3.9-7.8 mmol/L) was 96% (interquartile range, 92%-97%), mean within-individual coefficient of variation was 17 ± 3%, median time spent with glucose levels greater than 140 mg/dL was 3.4% (49 min/day), and median time less than 70 mg/dL (3.9 mmol/L) was 0.4% (6 min/day).
Conclusion:
Collecting normative sensor glucose data and describing glycemic measures for young children fill an important informational gap and will be useful as a benchmark for future clinical studies.
More Related Videos
Related Concept Videos
Glucose Homeostasis: Regulation of Blood Glucose
During fasting, when blood glucose levels are low, the pancreas secretes glucagon. it...
Diabetes: Symptoms, Diagnosis, and Complications
Hypoglycemia and Glucagon
Diabetes Mellitus: Type 2 and Gestational
Hormones Regulating Blood Glucose
In addition to accelerating glucose uptake and utilization, insulin has...
Pathophysiology of Diabetes
Type 1 diabetes is characterized by autoimmune-mediated destruction of pancreatic β cells, with environmental factors potentially triggering this process in genetically susceptible individuals. Despite many not having a family history, certain genes increase susceptibility,...