Related Experiment Video
Updated: Sep 24, 2025

12:29
Magnetic Resonance Imaging Quantification of Pulmonary Perfusion using Calibrated Arterial Spin Labeling
Published on: May 30, 2011
13.9K
Saturated multi-delay renal arterial spin labeling technique for simultaneous perfusion and T1 quantification in
Zihan Ning1, Shuo Chen1,2, Zhensen Chen3
1Center for Biomedical Imaging Research, Department of Biomedical Engineering, Tsinghua University School of Medicine, Beijing, China.
Magnetic Resonance in Medicine
|May 4, 2022
Summary
This study introduces the SAMURAI technique, a fast 4-minute MRI method for simultaneous kidney T1 mapping and perfusion quantification. It offers high accuracy and repeatability, improving renal assessment efficiency.
Area of Science:
- Magnetic Resonance Imaging
- Renal Physiology
- Medical Diagnostics
Background:
- Accurate renal assessment requires simultaneous T1 mapping and perfusion quantification.
- Existing methods are often time-consuming, limiting clinical utility.
- Arterial Spin Labeling (ASL) and T1 mapping are valuable MRI techniques for renal evaluation.
Purpose of the Study:
- To develop a free-breathing, simultaneous multi-delay arterial spin labeling (ASL) and T1 mapping technique for renal assessment.
- To achieve this in a single, time-efficient 4-minute scan at 3 Tesla using a stepwise kinetic model.
- To validate the feasibility and repeatability of the proposed technique.
Main Methods:
- A novel SAturated Multi-delay Renal arterial spin labeling (SAMURAI) sequence was implemented using FAIR preparation and Look-Locker SPGR acquisition.
- Saturation-based T1 mapping was achieved through pre-saturation at the imaging slice.
- A 4-step kinetic model was employed to characterize water transition and correct for ASL signal variations, followed by dictionary-based T1 estimation and model fitting for perfusion quantification.
Main Results:
- The SAMURAI technique demonstrated accurate T1 mapping (R² = 0.98 vs. IR-SE) and reliable ASL/T1 quantification (ICC 0.875-0.958) compared to established methods.
- It successfully detected low renal blood flow and increased T1 in patients with renal diseases.
- The technique achieved excellent scan-rescan repeatability (ICC 0.905-0.992) and significantly reduced scan time (4 min 6 s vs. 45 min).
Conclusions:
- The SAMURAI technique is a feasible and repeatable method for simultaneous renal T1 and perfusion quantification.
- Its high time-efficiency makes it a valuable tool for improved renal assessment.
- This technique offers a significant advancement in rapid, non-invasive kidney MRI.
Related Concept Videos
Imaging Studies VII: Vascular Imaging
77
DefinitionRenal angiography, also known as renal arteriography, is an imaging technique used to obtain a comprehensive view of blood flow and the vascular structure of blood vessels in the kidneys and surrounding areas.PurposeRenal angiography detects blood vessel abnormalities in the kidneys, such as aneurysms, stenosis, thrombosis, vascular tumors, and renal artery stenosis. It evaluates kidney function and guides interventional treatments like angioplasty or stent placement.Pre-Procedure...
77
Magnetic Resonance Imaging
7.4K
Magnetic resonance imaging (MRI) is a noninvasive medical imaging technique based on a phenomenon of nuclear physics discovered in the 1930s, in which matter exposed to magnetic fields and radio waves was found to emit radio signals. In 1970, a physician and researcher named Raymond Damadian noticed that malignant (cancerous) tissue gave off different signals than normal body tissue. He applied for a patent for the first MRI scanning device in clinical use by the early 1980s. The early MRI...