Activity Measurement of Iodine Fission Products in 2LiF-BeF2 Salt and Its Application in Redox Potential Surveillance

Junxia Geng1,2,3, Zhongqi Zhao1,2,3, Zhiqiang Cheng1,2,3

  • 1Shanghai Institute of Applied Physics, Chinese Academy of Sciences, Shanghai 201800, China.

Related Concept Videos

Redox Titration: Iodimetry and Iodometry01:23

Redox Titration: Iodimetry and Iodometry

Iodometry and iodimetry are analytical methods used to determine the concentration of oxidizing or reducing agents using iodine. In iodometric titrations, the oxidizing analyte solution is usually acidified and treated with an excess of iodide ions, which generates an equivalent amount of iodine in equilibrium with triiodide. The released iodine is subsequently titrated directly against a standardized reducing agent. As the dilute iodine color becomes pale yellow, a few drops of freshly...
2.9K
Flame Photometry: Lab01:16

Flame Photometry: Lab

In a flame photometer, when a solution like potassium chloride is aspirated into the flame, the solvent evaporates, leaving behind dehydrated salt. This salt dissociates into free gaseous atoms in their ground state. Some of these atoms absorb energy from the flame, leading to their excitation. The excited atoms return to the ground state, emitting photons at characteristic wavelengths. Because only electronic transitions are involved, the resulting emission lines are very narrow. The intensity...
416
Electrolysis03:00

Electrolysis

In a galvanic cell, the electrical work is done by a redox system on its surroundings as electrons produced by the spontaneous redox reactions are transferred through an external circuit. Alternatively, an external circuit does work on a redox system by imposing a voltage sufficient to drive an otherwise nonspontaneous reaction in a process known as electrolysis. For instance, recharging a battery involves the use of an external power source to drive the spontaneous (discharge) cell reaction in...
27.4K
Redox Titration: Overview01:21

Redox Titration: Overview

Redox titration is a chemical analysis technique used to determine the concentration of an unknown substance by measuring the electron transfer in a redox (reduction-oxidation) reaction. The process involves gradually adding a titrant with a known concentration of an oxidizing or reducing agent, to the analyte, the solution with an unknown concentration, until reaching the endpoint, which indicates the completion of the reaction between the two substances. Ensuring the analyte is in a single...
3.5K