Prediction of post-induction hypotension by point-of-care echocardiography: A prospective observational study
Younes Aissaoui1, Mathieu Jozwiak2, Mohammed Bahi3
1Pôle Anesthésie Réanimation, Hôpital Militaire Avicenne, 1 Avenue Al Mouqaouama, 40015, Marrakesh, Morocco; Laboratoire Biosciences et Santé, Faculté de Médecine et de Pharmacie, Université Cadi Ayyad, 40000, Marrakesh, Morocco.
Background:
Post-induction hypotension (PIH) is a common side effect of general anaesthesia and is associated with poor perioperative outcomes. We assessed the ability of two point-of-care echocardiographic variables to predict the occurrence of PIH: the passive leg raising-induced changes in the velocity-time integral of the left ventricular outflow tract (ΔVTI-PLR) and the inferior vena cava collapsibility index (IVC-CI).
Methods:
We studied 64 patients > 50 years scheduled for elective abdominal surgery. ΔVTI-PLR and IVC-CI were prospectively obtained before general anaesthesia induction. PIH was defined by a systolic arterial pressure < 90 mmHg or a mean arterial pressure < 65 mmHg or by a decrease in systolic or mean arterial pressure > 30% from pre-induction level. Intraclass correlation coefficients (ICCs) were calculated to assess the reproducibility of echocardiographic measurements. Receiver operating characteristic (ROC) curves with 95% confidence intervals (CIs) were generated to test the ability of ΔVTI-PLR and IVC-CI to predict the occurrence of PIH.
Results:
PIH occurred in 33 (51%) patients. The ICCs for VTI and IVC measurements showed excellent reproducibility. The occurrence of PIH was accurately predicted by ΔVTI-PLR with an area under the ROC curve (AUROC) of 0.89 (95% CI: 0.80-0.97), a threshold value of 18% with a sensitivity of 88% (95% CI: 71-97%) and a specificity of 84% (95% CI: 66-94%). The occurrence of PIH was poorly predicted by IVC-CI with an AUROC of 0.68 (95% CI: 0.54-0.80) and a threshold value of 42%.
Conclusions:
ΔVTI-PLR, unlike IVC-CI, could reliably predict the occurrence of PIH. The use of ΔVTI-PLR could help individualise anaesthesia management to prevent PIH.
More Related Videos
09:31Hemodynamic Precision in the Neonatal Intensive Care Unit using Targeted Neonatal Echocardiography
Published on: January 27, 2023
11:50High-frequency High-resolution Echocardiography: First Evidence on Non-invasive Repeated Measure of Myocardial Strain, Contractility, and Mitral Regurgitation in the Ischemia-reperfused Murine Heart
Published on: July 9, 2010
Related Concept Videos
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion,...
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.