Related Experiment Video
Updated: Sep 24, 2025

Patient Directed Recording of a Bipolar Three-Lead Electrocardiogram using a Smartwatch with ECG Function
Published on: December 11, 2019
Prospective evaluation of the effect of smartphone electrocardiogram usage on anticoagulant medication compliance
Andy T Tran1,2,3, Osama M Okasha1,2, Daniel A Steinhaus1
1Cardiovascular Research, Saint Luke's Mid America Heart Institute, 4401 Wornall Rd, 9th Floor, Kansas City, 64111, MO, USA.
Insights
Smartphone ECGs did not improve anticoagulation compliance in atrial fibrillation patients. However, higher monitor use correlated with better medication adherence, suggesting potential benefits for patient engagement.
Area of Science:
- Cardiology
- Digital Health
- Pharmacology
Background:
- Atrial fibrillation (AF) management requires consistent anticoagulation.
- Patient adherence to anticoagulant therapy is often suboptimal.
- Smartphone electrocardiograms (ECGs) offer potential for enhanced patient monitoring.
Purpose of the Study:
- To evaluate if smartphone ECG monitoring improves anticoagulant compliance in AF patients.
- To assess the relationship between smartphone ECG use and medication adherence.
Main Methods:
- A randomized controlled trial involving 100 AF patients with CHA 2 DS 2 -VASc score 2.
- Intervention group used a smartphone ECG (AliveCor Kardia) 5 times/week; control group received usual care.
- All participants received 6 months of apixaban via pill boxes.
Main Results:
- Median medication compliance was high (99.7%) and not significantly different between groups.
- No significant difference in missing doses between monitor and control groups.
- Higher smartphone ECG monitor compliance was associated with better medication compliance (p=0.02).
Conclusions:
- Smartphone ECG monitoring did not significantly improve anticoagulant medication compliance in this AF population.
- Greater adherence to using the smartphone ECG monitor correlated with better medication adherence.
Purpose:
Compliance with anticoagulation treatment for atrial fibrillation is highly variable. Smartphone electrocardiograms that allow patients to have greater insight into their arrhythmia burden may improve anticoagulant compliance.
Methods:
Patients were enrolled if they had atrial fibrillation with a CHA2DS2-VASc score of 2 or more, were eligible for anticoagulation and had a smartphone. Participants were randomly assigned to receive a smartphone electrocardiogram (AliveCor Kardia) to record their electrocardiograms 5 times/week or to the control group. All patients received 6 months of anticoagulant (apixaban) dispensed as 1-month pre-loaded pill boxes.
Results:
A total of 100 patients were enrolled from July 2017 to August 2019, but 5 patients in the monitor arm and 1 in the control arm withdrew prematurely. The monitor and control groups did not differ in age, gender, CHA2DS2-VASc score, or comorbidities. Median medication compliance was 99.7%, with nonsignificantly greater compliance in the monitor group (100%) than in the control group (99.7%) (p-value = 0.247). There was also no significant difference between missing any dose and use/nonuse of the smartphone monitor (48.9% vs. 55.1%; p-value = 0.692). Mean monitor compliance was 86.8% ± 14.0% with an average of 4.34 recorded electrocardiograms per week. Monitor group patients with perfect medication compliance had significantly higher monitor compliance than those patients who missed doses (median 95.3% vs 86.7%; p-value = 0.02).
Conclusions:
In a study population with higher-than-expected medication compliance, the use of smartphone electrocardiogram did not demonstrate an improvement in medication compliance as compared to usual care. Greater monitor compliance was associated with greater medication compliance.
Clinical Trial Registration:
BOAT-OAR ClinicalTrials.gov number, NCT03515083.
Related Concept Videos
Holter Monitor: 24-Hour Monitoring
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Dysrhythmias V: Evaluating Dysrhythmias
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and...
Coronary Artery Disease IV: Preventive Measures