Related Experiment Video
Updated: Sep 24, 2025

Modified Octopus Technique for Thoracoabdominal Aortic Aneurysm
Published on: August 1, 2025
Endovascular repair of a complex renal artery aneurysm using PipelineTM Embolization Device (PED) assisted coil
Jeff Liang1, Gary Duckwiler2, Jeremy Middleton1
1Division of Interventional Radiology, UCLA Medical Center, David Geffen School of Medicine at UCLA, Los Angeles, CA, USA.
Background:
We describe the treatment of a renal artery aneurysm with complex anatomy using coils and the PipelineTM Embolization Device (Medtronic, Irvine, CA), a flow-diverting stent typically used for the treatment of intracranial aneurysms.
Methods:
A 62-year-old female with history of an asymptomatic right renal artery aneurysm that was discovered incidentally 10 years ago was found to have enlargement of the aneurysm (1.9cm to 2.7cm) on a repeat surveillance CT scan. She was successfully treated with combined Pipeline Embolization Device and coil embolization of the aneurysm sac.
Results:
Post-procedural angiography showed complete occlusion of the aneurysm with maintenance of perfusion to the entire kidney.
Conclusion:
PipelineTM assisted coil embolization may be an option for parenchyma-sparing treatment of renal artery aneurysms with complex anatomy.
Related Concept Videos
Aneurysm III: Interprofessional Care
Imaging Studies VII: Vascular Imaging