Related Experiment Video
Updated: Sep 24, 2025

Near Infrared Optical Projection Tomography for Assessments of β-cell Mass Distribution in Diabetes Research
Published on: January 12, 2013
Regression-based neural network for improving image reconstruction in diffuse optical tomography
Ganesh M Balasubramaniam1, Shlomi Arnon1
1Department of Electrical and Computer Engineering, Ben-Gurion University of the Negev, Be'er Sheva, 8441405, Israel.
Abstract:
Diffuse optical tomography (DOT) is a non-invasive imaging technique utilizing multi-scattered light at visible and infrared wavelengths to detect anomalies in tissues. However, the DOT image reconstruction is based on solving the inverse problem, which requires massive calculations and time. In this article, for the first time, to the best of our knowledge, a simple, regression-based cascaded feed-forward deep learning neural network is derived to solve the inverse problem of DOT in compressed breast geometry. The predicted data is subsequently utilized to visualize the breast tissues and their anomalies. The dataset in this study is created using a Monte-Carlo algorithm, which simulates the light propagation in the compressed breast placed inside a parallel plate source-detector geometry (forward process). The simulated DL-DOT system's performance is evaluated using the Pearson correlation coefficient (R) and the Mean squared error (MSE) metrics. Although a comparatively smaller dataset (50 nos.) is used, our simulation results show that the developed feed-forward network algorithm to solve the inverse problem delivers an increment of ∼30% over the analytical solution approach, in terms of R. Furthermore, the proposed network's MSE outperforms that of the analytical solution's MSE by a large margin revealing the robustness of the network and the adaptability of the system for potential applications in medical settings.
Related Concept Videos
Imaging Studies III: Computed Tomography
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Biological Samples with Optical Microscopy
In optical microscopy, the specimen to be viewed is placed on a glass slide and clipped on the stage...
Electron Microscope Tomography and Single-particle Reconstruction
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...