Related Experiment Video
Updated: Sep 24, 2025

A Method to Estimate Cadaveric Femur Cortical Strains During Fracture Testing Using Digital Image Correlation
Published on: September 14, 2017
Stochastic failure analysis of proximal femur using an isogeometric analysis based nonlocal gradient-enhanced damage
Aakash Soni1, Sachin Kumar1, Navin Kumar1
1Department of Mechanical Engineering, Indian Institute of Technology Ropar, Punjab, India, 140001.
Background And Objective:
Medical imaging-based finite element methods are more accurate tools for fracture risk prediction than the traditional aBMD based methods. However, these methods have drawbacks like geometric errors, high computational cost, mesh-dependent results, etc. In this article, the authors have proposed an isogeometric analysis-based nonlocal gradient-enhanced damage model to overcome some of these issues. Moreover, there are uncertainties in the values of input parameters for such analysis due to various measurement errors. Hence, stochastic analysis is performed to quantify the effect of these parametric uncertainties on the fracture behavior of the proximal femur.
Methods:
Computed Tomography images of a patient are used to create a 2D proximal femur model with a heterogeneous description of material properties. A numerical model based on gradient-enhanced nonlocal continuum damage mechanics is used for fracture analysis of proximal femur to overcome the issues related to mesh dependency in traditional continuum damage mechanics models. Further, a multipatch isogeometric solver is developed to solve the governing equations. Monte Carlo simulations are used to understand the effect of parametric uncertainties on the fracture behavior of the proximal femur.
Results:
The developed numerical framework is used to solve the fracture problem of proximal femur under single leg stance loading conditions. The obtained results are validated by comparing the load-displacement response and the crack path with that given in the literature. Stochastic analysis is performed by considering a ±5% variation in the elastic modulus, damage initiation strain, and the neck-shaft angle values.
Conclusion:
The proposed numerical framework can correctly predict the damage initiation and propagation in a proximal femur. The results reveal that the heterogeneous nature of material properties of bone plays a significant role in determining the fracture characteristics of the proximal femur. Further, the results of the stochastic analysis reveal that the parametric uncertainties in the neck-shaft angle have a much more significant influence on the results of the analysis than the parametric uncertainties in the elastic modulus and damage initiation strain.
Related Concept Videos
Normal Strain under Axial Loading
Bending of Curved Members - Strain Analysis
The important part of bending analysis for such a member...
Deformation of Member under Multiple Loadings
In the case of a member with a variable cross-section, the strain is not constant but depends on the position. The deformation of an...
Generalized Hooke's Law
Plastic Deformations
General Case of Eccentric Axial Loading
Consider a member subjected to equal and opposite forces that are applied along a line that does not coincide with the member's neutral axis. In unsymmetrical...