Related Experiment Video
Updated: Sep 24, 2025

Evaluation of the Efficacy of Organic Peroxyacids for Eradicating Dairy Biofilms Using an Approach Combining Static and Dynamic Methods
Published on: December 9, 2022
Gravimetric analysis of stability of polymeric materials during exposure to chemical disinfectants at different
Kang Hoon Lee1, Imtiaz Afzal Khan2, Yong-Soo Lee2
1Department of Energy and Environmental Engineering, Catholic University, 43 Jibong-ro, Bucheon-si, 14662, Republic of Korea.
Abstract:
The goal of this study was to evaluate the impact of thermal and chemical aging processes on high-density polyethylene (HDPE), low-density polyethylene (LDPE), unplasticized polyvinyl chloride (U-PVC), and high-impact polyvinyl chloride (Hi-PVC) pipes. The materials were exposed to 1-10 ppm chemical disinfectants [chlorine dioxide (ClO2) and hypochlorite (HOCl)] at 40-80 °C for 1200 h. The diffusion properties of the materials were systematically analyzed based on the change in their sorption characteristics and activation energies according to the Arrhenius model. Moreover, the structural changes were analyzed with scanning electron microscopy (SEM), Fourier transform infrared (FTIR) radiation, and thermogravimetric analysis (TGA). The results show that the materials have Fickian characteristics in the aging environment. Specifically, the water sorption rates of HDPE and LDPE increase first and then decrease after reaching saturation (Ms); those of U-PVC and Hi-PVC its increasing continuously with different rate. This behavior of materials was prominent for ClO2 at high temperature and disinfectant dose because of polymeric chains crosslinking and rearrangement, extraction of monomers, and stable compounds removal during aging under exposed conditions. The deleterious effects decreased the activation energies of the materials and increased the concentrations of carbonyl groups [CO] via the formation of ketones, aldehydes, and carboxylic acids. The decomposition temperature increased with the changes in the material morphology and elemental contents under the investigated conditions. Moreover, LDPE and Hi-PVC were more severely affected in the thermal aging process with 10 mg.L-1 ClO2 at 80 °C.
More Related Videos
09:16Synthesis of Terpolymers at Mild Temperatures Using Dynamic Sulfur Bonds in PolyS-Divinylbenzene
Published on: May 20, 2019
07:15A Testing Platform for Durability Studies of Polymers and Fiber-reinforced Polymer Composites under Concurrent Hygrothermo-mechanical Stimuli
Published on: December 11, 2014
Related Concept Videos
Methods of Sterilization II: Chemical Methods
Using chemical sterilization rather than heat to clean out equipment is recommended. It eradicates and removes all bacteria,...
Physical Methods for Controlling Microbial Growth: Temperature
Chemical Agents for Microbial Control
Methods of Sterilization I: Physical Methods
Steam sterilization uses non-toxic, low-cost moist heat in the form of saturated steam under pressure, which is fast, microbicidal, and sporicidal, and quickly warms and penetrates fabrics. Autoclaves, or steam sterilizers, expose each item to direct steam contact for a predetermined time at the necessary...
Cleaning, Sterilization, and Disinfection
Cleaning
The cleaning process usually involves using water with detergents or enzymatic cleaner and removing foreign material from objects and surfaces, including organic material such as body fluids or inorganic material like soil. Cleaning is performed before high-level disinfection and sterilization because foreign materials on the cover of the devices interfere with process...
Polymer Classification: Stereospecificity