Related Experiment Video
Updated: Sep 24, 2025

Candidate Gene Testing in Clinical Cohort Studies with Multiplexed Genotyping and Mass Spectrometry
Published on: June 21, 2018
Development and Validation of a Quantitative Method for Multiple Allergen Detection in Food Using Concatemer-Based
Maxime Gavage1, Kaatje Van Vlierberghe2, Marc Dieu3
1CER Groupe, Rue du Point du Jour 8, 6900 Marloie, Belgium.
Background:
Accurate food labeling is essential to protect allergic consumers. However, allergen contaminations may occur during the whole food production process. Reliable, sensitive, and robust methods for detecting multiple allergens in food are needed.
Objective:
This work aims to develop and validate an LC coupled to tandem mass spectrometry (MS/MS) method for the detection and quantification of hazelnuts, peanuts, milk, and eggs in processed food products.
Methods:
In-house-produced incurred test materials, cookies and chocolates, were used for the method development and validation. The quantification was based on the standard addition strategy using qualified reference materials as allergen protein standards and an innovative stable isotope-labeled concatemer as an internal standard.
Results:
A method targeting 19 allergen-specific peptides was developed and validated in two laboratories, which strengthens its robustness. The AOAC INTERNATIONAL performance requirements for repeatability, intermediate precision, reproducibility, and recovery were reached for at least one peptide per allergen across both matrixes, and quantification limits complied with the action levels of the Food Industry Guide to the Voluntary Incidental Trace Allergen Labelling (VITAL®) Program Version 3.0.
Conclusion:
The combination of incurred test materials, standard addition strategy, and stable isotope-labeled concatemer as an internal standard allowed us to develop and validate a robust method for detecting and quantifying multiple allergens in food with sufficient sensitivity to protect allergic consumers.
Highlights:
The combination of characterized incurred test material, calibration with certified reference material, a single stable isotope labelled concatemer and cross-lab validation result in the required standardization and harmonization in food allergen detection according to the stakeholders' group to assess the robustness of our method.
More Related Videos
07:10Application of Biochip Microfluidic Technology to Detect Serum Allergen-specific Immunoglobulin E sIgE
Published on: April 21, 2019
08:56Detection of Regulated Ergot Alkaloids in Food Matrices by Liquid Chromatography-Trapped Ion Mobility Spectrometry-Time-of-Flight Mass Spectrometry
Published on: November 22, 2024