Related Experiment Video
Updated: Sep 24, 2025

A Model to Simulate Clinically Relevant Hypoxia in Humans
Published on: December 22, 2016
Detection of pediatric obstructive sleep apnea using a multilayer perceptron model based on single-channel oxygen
Yunxiao Wu1, Yifan Jia2, Xiaolin Ning3
1Beijing Key Laboratory of Pediatric Diseases of Otolaryngology, Head and Neck Surgery, Beijing Pediatric Research Institute, Beijing Children's Hospital, Capital Medical University, National Center for Children's Health, 56 Nanlishi Road, Xicheng District, Beijing 100045, China; School of Instrumentation Science and Opto-electronics Engineering, Beihang University (BUAA), 37 Xueyuan Road, Haidian District, Beijing 100191, China.
Purpose:
This study was performed to develop and evaluate a method of detecting pediatric obstructive sleep apnea (OSA) using a multilayer perceptron (MLP) model based on single-channel nocturnal oxygen saturation (SpO2) with or without clinical data.
Methods:
Polysomnography data for 888 children with OSA and 417 unaffected children were included. An MLP model was proposed based on the features obtained from SpO2 and combined features of SpO2 and clinical data to screen symptomatic children for OSA. The performance of the overall classification was evaluated with the receiver operating characteristics curve and the metrics of sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), positive likelihood ratio (LR+), negative likelihood ratio (LR-), and accuracy.
Results:
The sensitivity, specificity, PPV, NPV, LR+, LR-, and accuracy of the MLP model for SpO2 of an obstructive apnea-hypopnea index (OAHI) cutoff value of 1, 5, and 10 were 0.62-0.96, 0.11-0.97, 0.70-0.81, 0.55-0.93, 1.08-21.0, 0.39-0.39, and 0.69-0.91, respectively. The area under the receiver operating characteristics curve of an OAHI cutoff value of 1, 5, and 10 was 0.720, 0.842, and 0.922, respectively. After adding the clinical data of age, sex, body mass index, weight category, adenoid grade, or tonsil scale, the performance of the MLP model was basically at the same level as only single-channel SpO2.
Conclusions:
Application of this MLP model using single-channel SpO2 in children with snoring has high accuracy in the diagnosis of moderate to severe OSA but a poor effect in the diagnosis of mild OSA. The combination of clinical data did not significantly improve the diagnostic performance of the MLP model.
Related Concept Videos
Sleep Apnea
The condition is more prevalent among...
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Assessment of Airway, Skin Color, and Use of Accessory Muscles
Introduction
The initial evaluation of a patient's respiratory system...
Physical Assessment of the Respiratory Tract II: Inspection
Chest Configuration
The chest configuration...
Cardiopulmonary Resuscitation II: ACLS Airway Management

