Related Experiment Video
Updated: Sep 24, 2025

Laparoscopic Repair of Para-Esophageal Hernia Using Absorbable Biosynthetic Mesh
Published on: September 11, 2021
Laparoscopic transabdominal preperitoneal repair for recurrent obturator hernia initially treated by open mesh plug
Kenta Doden1, Takahiro Yoshimura1, Shiori Shibata1
1Department of Surgery, Yokohama Sakae Kyosai Hospital, Yokohama, Japan.
Abstract:
An 80-year-old woman presented to our emergency department with vomiting which had begun half a day prior to presentation. She had undergone open mesh plug repair for a right obturator hernia 1 year prior to presentation. Computed tomography detected recurrence of the right obturator hernia. Since intestinal viability was maintained, manual reduction of the incarcerated intestine was performed. The patient was admitted to our department to monitor delayed intestinal perforation. Laparoscopic transabdominal preperitoneal repair for obturator hernia was performed 5 days after admission. A self-fixating mesh was placed over the obturator hernia defect and femoral ring without tacking. The patient was discharged on postoperative day 6 without postoperative complications. At the 4-month follow-up, no signs of hernia recurrence or neuropathy were observed. Laparoscopic transabdominal preperitoneal repair for recurrent obturator hernia status post-open mesh plug repair by using self-fixating mesh is a safe and suitable procedure.