Calibration of camera internal parameters based on grey wolf optimization improved by levy flight and mutation

Daolei Wang1, Jingwei Yue1, Pingping Chai1

  • 1College of Energy and Mechanical Engineering, Shanghai University of Electric Power, Shanghai, 200090, China.

Scientific Reports
|May 13, 2022
PubMed
Summary

This study introduces a novel Grey Wolf Optimizer with Levy flight and mutation for improved camera internal parameter calibration. The enhanced algorithm achieves superior accuracy and effectiveness compared to existing methods.

Related Concept Videos

Calibration Curves: Linear Least Squares01:20

Calibration Curves: Linear Least Squares

A calibration curve is a plot of the instrument's response against a series of known concentrations of a substance. This curve is used to set the instrument response levels, using the substance and its concentrations as standards. Alternatively, or additionally, an equation is fitted to the calibration curve plot and subsequently used to calculate the unknown concentrations of other samples reliably.
For data that follow a straight line, the standard method for fitting is the linear...
2.5K
Instrument Calibration01:12

Instrument Calibration

Instrument calibration is essential for ensuring that instruments produce accurate and consistent results. It is vital in manufacturing, healthcare, testing laboratories, and scientific research. Calibration processes are specific to each instrument and help enhance data accuracy. Each instrument has a unique calibration process tailored to its design and function to improve data accuracy.
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
285
Glassware Calibration01:11

Glassware Calibration

Accurate calibration of glassware, such as volumetric flasks, pipettes, and burettes, is essential to ensure accurate measurements in the analytical laboratory. Calibration helps maintain consistency across measurements and prevents errors arising from inaccurate volumes.
Volumetric flasks: Volumetric flasks are designed to prepare aqueous solutions of precise volumes accurately with a calibration line on the neck. To calibrate a volumetric flask, it is important to fill it with distilled...
698
Calibration Curves: Correlation Coefficient01:10

Calibration Curves: Correlation Coefficient

In a linear calibration curve, there is a value called the calibration coefficient, denoted by 'r,' which measures the strength and the direction of association between two variables. The correlation coefficient value ranges from −1 to +1. A value of +1 indicates a perfect positive linear correlation, −1 denotes a perfect negative correlation, and 0 implies no correlation between the two variables. A positive correlation value establishes that as one variable increases, the...
2.5K
Differential Leveling01:12

Differential Leveling

Differential leveling is a precise method in surveying used to determine the elevation difference between two points. Its primary goal is to establish accurate vertical measurements to create level surfaces or grade lines critical for designing and constructing infrastructures such as roads, bridges, and buildings.The procedure for differential leveling begins with setting up and leveling the instrument at a point where the benchmark can be seen. The level rod is held on the benchmark (BM), and...
347
Introduction and Methods of Leveling01:26

Introduction and Methods of Leveling

Leveling is a surveying procedure used to determine elevation differences between distant points. Elevation refers to the vertical distance above or below a reference datum, typically mean sea level (MSL). In the United States, elevations are often referenced to the mean sea level station at Father Point Rimouski along the St. Lawrence Seaway. To make the datum accessible, permanent markers are established throughout the region. These markers, called benchmarks, have known elevations. If the...
240