Determination of major and trace element variability in healthy human urine by ICP-QMS and specific gravity

Rebekah E T Moore1, Mark Rehkämper1, Katharina Kreissig1

  • 1Department of Earth Science and Engineering, Imperial College London London SW7 2AZ UK r.moore13@imperial.ac.uk +44(0) 7974 779 418.

RSC Advances
|May 13, 2022
PubMed

Related Concept Videos

Urine Studies I: Urinalysis01:29

Urine Studies I: Urinalysis

Urinalysis is a widely used diagnostic test that analyzes urine's physical, chemical, and microscopic characteristics. Healthcare providers use it to detect and monitor various health conditions, including renal disease, urinary tract infections (UTIs), diabetes, and metabolic or systemic disorders.Components of UrinalysisUrinalysis consists of three primary components: physical, chemical, and microscopic examination. Each provides unique insights into the urine sample and, by extension, the...
230
Physiology of the Genitourinary System III: Urine Concentration and Dilution01:20

Physiology of the Genitourinary System III: Urine Concentration and Dilution

The kidneys concentrate or dilute urine to maintain water and electrolyte balance. Nephrons, particularly the loop of Henle, play a crucial role in this process through the countercurrent multiplication system. This system establishes a high osmolarity in the renal medulla, which is essential for water reabsorption. In the loop of Henle’s descending limb, water is reabsorbed into the surrounding medulla due to its permeability to water. In contrast, the ascending limb actively transports...
53
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences01:20

Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences

Inductively coupled plasma–mass spectrometry (ICP–MS) is a highly selective and sensitive technique for accurate elemental analysis. Though the analysis of ICP–MS mass spectra is comparatively straightforward, it is affected by spectroscopic and non-spectroscopic interferences. Spectroscopic interferences arise when the plasma contains ionic species with an m/z value the same as the analyte ion. Spectroscopic interference can be categorized as isobaric, polyatomic ions, and...
653
Gravimetry: Overview01:05

Gravimetry: Overview

Gravimetric analysis is a quantitative method where the analyte is isolated and weighed directly or after conversion into a substance of known composition. Gravimetric analysis can be classified as precipitation, electrogravimetry, volatilization, and particulate gravimetry, based on the method used to isolate the analyte.
In precipitation gravimetry, the analyte is converted into a precipitate and weighed. For example, the silver content in a sample can be estimated by precipitating and...
6.9K
Formation of Dilute Urine01:20

Formation of Dilute Urine

The formation of dilute urine is a critical renal adaptation that maintains fluid balance, particularly during periods of high fluid intake. This process primarily involves the juxtamedullary nephrons. By adjusting the permeability of water and ions in response to physiological conditions, the kidneys can either conserve or excrete water, resulting in concentrated or dilute urine.
Filtrate Osmolarity in the PCT
Initially, as the filtrate passes through the proximal convoluted tubule (PCT), its...
1.9K
One-Compartment Open Model: Urinary Excretion Data and Determination of k01:11

One-Compartment Open Model: Urinary Excretion Data and Determination of k

The one-compartment open model leverages urinary excretion data to estimate renal clearance, which gauges the kidney's capacity to expel a drug. This method offers several benefits, including directly measuring drug elimination and assessing the kidney's contribution to overall drug clearance. However, this approach has limitations. It assumes sole renal excretion of the drug, which is not true for all drugs. Accurate urinary excretion and plasma drug concentration measurement can also...
307