Mathematical Modeling of Monovalent Permselectivity of a Bilayer Ion-Exchange Membrane as a Function of Current

Andrey Gorobchenko1, Semyon Mareev1, Victor Nikonenko1

  • 1Membrane Institute, Kuban State University, 149 Stavropolskaya St., 350040 Krasnodar, Russia.

Related Concept Videos

Ion Exchange01:17

Ion Exchange

Ion exchange chromatography separates charged molecules from a solution by reversibly exchanging them with mobile, or 'active', ions associated with the oppositely charged stationary phase. This method can be used to separate ions, soften and deionize water, and purify solutions. The polymers comprising the ion-exchange column are high-molecular-weight and chemically stable polymers, crosslinked to be porous and essentially insoluble. They are also functionalized with either acidic or...
676
Potentiometry: Membrane Electrodes01:15

Potentiometry: Membrane Electrodes

Membrane electrodes, also known as p-ion electrodes, use membranes that selectively interact with free analyte ions, generating a potential difference across the membrane. The resulting membrane potential, known as the asymmetry potential, is not zero even when analyte concentrations on both sides of the membrane are equal. The membrane's response is typically not selective to a single analyte but proportional to the concentration of all ions in the sample solution capable of interacting at...
833
Ion-Exchange Chromatography01:09

Ion-Exchange Chromatography

Ion-exchange chromatography, or IEC, is a technique for separating ions based on their affinity for the stationary phase. The stationary phase is a cross-linked polymer resin with covalently attached ionic functional groups. The functional groups can be either positively charged (cation exchangers) or negatively charged (anion exchangers). A cation exchanger consists of a polymeric anion and active cations, while an anion exchanger is a polymeric cation with active anions. The choice of...
819
The Resting Membrane Potential01:21

The Resting Membrane Potential

Overview
135.6K
Physiological Pharmacokinetic Models: Blood Flow-Limited Versus Diffusion-Limited Models00:57

Physiological Pharmacokinetic Models: Blood Flow-Limited Versus Diffusion-Limited Models

Physiological pharmacokinetic models, often called flow-limited or perfusion models, typically assume a swift drug distribution between tissue and venous blood, creating a rapid drug equilibrium. This premise is based on the idea that drug diffusion is extremely fast, and the cell membrane presents no barrier to drug permeation. In this scenario, where no drug binding occurs, the drug concentration in the tissue equals that of the venous blood leaving the tissue. This greatly simplifies the...
157
Boundary Conditions for Current Density01:25

Boundary Conditions for Current Density

Current density becomes discontinuous across an interface of materials with different electrical conductivities. The normal component of the current density is continuous across the boundary.
978