Related Experiment Video
Updated: Sep 23, 2025

Asthma Detection Research Based on Voice Signal Processing and Machine Learning
Published on: July 22, 2025
Updating Indoor Air Quality (IAQ) Assessment Screening Levels with Machine Learning Models
Ling-Tim Wong1, Kwok-Wai Mui1, Tsz-Wun Tsang1
1Department of Building Environment and Energy Engineering, The Hong Kong Polytechnic University, Hung Hom, Hong Kong.
Abstract:
Indoor air quality (IAQ) standards have been evolving to improve the overall IAQ situation. To enhance the performances of IAQ screening models using surrogate parameters in identifying unsatisfactory IAQ, and to update the screening models such that they can apply to a new standard, a novel framework for the updating of screening levels, using machine learning methods, is proposed in this study. The classification models employed are Support Vector Machine (SVM) algorithm with different kernel functions (linear, polynomial, radial basis function (RBF) and sigmoid), k-Nearest Neighbors (kNN), Logistic Regression, Decision Tree (DT), Random Forest (RF) and Multilayer Perceptron Artificial Neural Network (MLP-ANN). With carefully selected model hyperparameters, the IAQ assessment made by the models achieved a mean test accuracy of 0.536-0.805 and a maximum test accuracy of 0.807-0.820, indicating that machine learning models are suitable for screening the unsatisfactory IAQ. Further to that, using the updated IAQ standard in Hong Kong as an example, the update of an IAQ screening model against a new IAQ standard was conducted by determining the relative impact ratio of the updated standard to the old standard. Relative impact ratios of 1.1-1.5 were estimated and the corresponding likelihood ratios in the updated scheme were found to be higher than expected due to the tightening of exposure levels in the updated scheme. The presented framework shows the feasibility of updating a machine learning IAQ model when a new standard is being adopted, which shall provide an ultimate method for IAQ assessment prediction that is compatible with all IAQ standards and exposure criteria.
More Related Videos
09:33Visualizing Field Data Collection Procedures of Exposure and Biomarker Assessments for the Household Air Pollution Intervention Network Trial in India
Published on: December 23, 2022
12:18A Machine Learning Approach to Design an Efficient Selective Screening of Mild Cognitive Impairment
Published on: January 11, 2020
Related Concept Videos
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement:
Assessment of Respiration
Subjective Assessment: Nurses interview the patient to gather information directly during the subjective assessment. It includes questions about the individual's medical history, medications, and symptoms, focusing on past respiratory conditions like...
Steps in Outbreak Investigation