Finite Element Modeling of Debonding Failures in FRP-Strengthened Concrete Beams Using Cohesive Zone Model
Mohammed A Al-Saawani1, Abdulaziz I Al-Negheimish1, Ahmed K El-Sayed1
1Center of Excellence for Concrete Research and Testing, Department of Civil Engineering, King Saud University, P.O. Box 800, Riyadh 11421, Saudi Arabia.
Abstract:
Intermediate crack (IC) debonding and concrete cover separation (CCS) are common types of debonding failures in concrete beams flexurally strengthened with fiber-reinforced polymer (FRP) composites. In this paper, a three-dimensional finite element (FE) model was developed to simulate the flexural behavior and predict the critical debonding failure in FRP-strengthened beams. The two critical debonding failures were considered in the FE model by implementing a cohesive zone model based on fracture mechanics considering the effect of the related parameters. The input values used for the cohesive zone model are modified in this study to obtain accurate and consistent predictions. The FE model was validated by comparison with experimental results tested by the authors for beams particularly prone to fail by either of the two critical debonding failures. The results obtained from the FE model agree well with the experimental results for both of the debonding failures and the corresponding capacities at failure. In general, the ratio of the experimental to numerical ultimate capacities was within 5%, and so was the ratio of the experimental to numerical mid-span deflections at debonding failures. The FE model developed in this study was then used to conduct a parametric study investigating the effect of shear span-to-depth ratio and spacing of steel stirrups on the ultimate capacity and type of debonding failure in FRP-strengthened beams. The results of the parametric study revealed that increasing the spacing of steel stirrups caused a significant decrease in the load capacity at concrete cover separation failure. In addition, varying the shear span-to-depth ratio was seen to have an important effect on the type of debonding failure and corresponding capacities for the FRP-strengthened beams having the same cross-section geometry and CFRP reinforcement.
Related Concept Videos
Fiber Reinforced Concrete
Plastic Deformations
Design Example: Distributing Reinforcements in Concrete Sections
Design of Prismatic Beams for Bending
Prismatic Beams: Problem Solving
The design begins with analyzing the beam as a free body to identify moments and force balances, thereby determining support reactions. Next, the...
Deformation of a Beam under Transverse Loading
The insights from the bending moment diagram extend to...