Related Experiment Video
Updated: Sep 23, 2025

Author Spotlight: Magnetometric Characterization of Intermediates in the Solid-State Electrochemistry of Redox-Active Metal-Organic Frameworks
Published on: June 9, 2023
Transition metal copper composite ionic liquid self-built ratiometric sensor for the detection of paracetamol
Xuan Chen1, Yangguang Li1, Xiang Li1
1Key Laboratory for Green Processing of Chemical Engineering of Xinjiang Bingtuan, School of Chemistry and Chemical Engineering, Shihezi University, Shihezi, China.
Abstract:
In this paper, a MOF derivative Cu-PF6-MOF composed of transition metal copper and ionic liquid [BMIM] PF6 was used to construct a ratiometric electrochemical sensor for paracetamol detection. Cu-PF6-MOF was synthesized by chemical bath method and characterized by scanning electron microscopy (SEM), transmission electron microscopy (TEM), Brunauer-Emmett-Teller (BET), X-ray Photoelectron Spectroscopy (XPS) and X-ray powder diffraction (XRD). Owing to the introduction of ionic liquid [BMIM] PF6 and the synthetic effect on transition metal copper and ionic liquid [BMIM] PF6, Cu-PF6-MOF has the higher conductivity, larger electroactive surface area and better intrinsic catalytic properties of the skeletal transition metal, exhibiting enhanced electrocatalytic response to the reduction of paracetamol. The stable reduction peak at -104 mV was used as the ratiometric signal for analytical paracetamol detection using differential pulse voltammetry (DPV), with a linear range of 0.1-100 μM and a detection limit of 0.03 μM (S/N = 3). In addition, the constructed sensor showed good reproducibility, stability and interference resistance, as well as ideal recoveries (98.20%-104.40%) for the analysis of paracetamol in water samples.
More Related Videos
10:31Detection and Recovery of Palladium, Gold and Cobalt Metals from the Urban Mine Using Novel Sensors/Adsorbents Designated with Nanoscale Wagon-wheel-shaped Pores
Published on: December 6, 2015
08:19Hollow Microneedle-based Sensor for Multiplexed Transdermal Electrochemical Sensing
Published on: June 1, 2012
Related Concept Videos
Complexometric Titration: Overview
Extraction: Advanced Methods
Qualitative Analysis
For instance, group IV...
High-Performance Liquid Chromatography: Types of Detectors
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...
Precipitation Titration: Endpoint Detection Methods