Related Experiment Video
Updated: Sep 23, 2025

Using High Resolution Computed Tomography to Visualize the Three Dimensional Structure and Function of Plant Vasculature
Published on: April 5, 2013
A New Method to Visualize the Internal Morphology of Crude Drugs Using High-Resolution X-Ray Computed Tomography
Hiroko Tokumoto1, Eiichi Yamamoto2, Takashi Hakamatsuka1
1Division of Pharmacognosy, Phytochemistry, and Narcotics, National Institute of Health Sciences.
Abstract:
The microscopic test method (microscopic examination) used to identify crude drugs is a common method in the identification of the original plant source by determining the characteristics from a small sample quantity. However, in recent years, the number of examiners who are familiar with the microscopic examination technique has decreased. In recent years, high-resolution X-ray computed tomography (HRXCT) has been used to visualize the internal structure of plants. HRXCT scans an object using X-rays and enables visualization of the internal structure of the crude drug using a computer. Therefore, in this report, HRXCT was used to easily observe the internal morphology of crude drugs using the Ephedra Herb as an example. The same internal morphological characteristics were observed using both, microscopic examination and HRXCT methods. Image analysis using HRXCT did not require specific techniques, such as sectioning, and the same tissue could be observed from any orientation using a single scan. It afforded remarkable technical simplification and reduction in time to inspect the organization's characteristics. Therefore, image analysis using HRXCT is a useful method for crude drug identifications.
Related Concept Videos
X-ray Diffraction of Biological Samples
According to Bragg's law, when X-rays strike the sample positioned on a stage, the rays are scattered by the electron clouds around the sample atoms. The X-ray diffraction or scattering is caused by constructive interference of the X-ray waves that reflect off the internal...
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Electron Microscope Tomography and Single-particle Reconstruction
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...

