Experimental demonstration of noncontact vital-sign measurement using pulse radar
Tzu-Ming Ou1, Wei-Wen Hu2, Chia-Hung Chang3
1Division of Gastroenterology, Department of Internal Medicine, Kaohsiung Armed Forces General Hospital, Kaohsiung, Taiwan.
Backgroud:
Recently, monitoring the vital-sign with the noncontact method is a popular technology.
Objective:
In this work, we present a fully pulse radar system including front-end sensing and back-end data processing. A series of ultra-wide band sensing pulses is generated and radiated to detect the subject's chest vibration which in turn obtains the required vital-sign signals.
Methods:
An artificial plywood with 3 centimeter thickness is placed between a transmitting/receiving antenna of the radar and subject to demonstrate the characteristic of noncontact sensing. The firmware and digital signal processing are also presented in this paper to optimize physiological data quality.
Results:
The experimental results show that the continuous heart rate and breathing rate can be monitored by this customized system radar module.
Conclusion:
A fully customized ultra-wide band radar for vital-sign application is presented. The radar system plan with wall parameter is also incorporated into the design consideration to meet the FCC requirement and SNR.
More Related Videos
Related Concept Videos
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Special considerations while measuring pulse
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...