Related Experiment Video
Updated: Sep 23, 2025

Defining Substrate Specificities for Lipase and Phospholipase Candidates
Published on: November 23, 2016
Characterization of the Interfacial Liquid Layer Formed on Hydrophobic Packing Material Surfaces by Liquid
Masami Shibukawa1, Hiroki Okutsu1, Shingo Saito1
1Graduate School of Science and Technology, Saitama University, 255 Shimo-Okubo, Sakura-ku, Saitama 338-8570, Japan.
Abstract:
We determine the bulk liquid phase volumes in octadecyl-bonded silica (C18 silica) columns equilibrated with acetonitrile-water and methanol-water (0-19%(v/v)) binary mixed solvents by a liquid chromatographic method with inorganic ions used as probes. The solvent composition and the thickness of the interfacial liquid layer formed on the C18-bonded silica surface are then determined from the bulk liquid phase volume, the total liquid phase volume, the surface area of the C18 silica packing material, and the retention volumes of the isotopically labeled eluent components for the columns. We used two C18 silica packing materials having identical bonding structures but different pore sizes and surface areas. Our results show that various hydrophilic organic compounds as well as inorganic ions recognize the interfacial liquid layer as being different from the bulk phase. The behavior of the solute compounds exhibiting substantially weak retention in reversed-phase liquid chromatography or the so-called negative adsorption, such as urea, sugars, and inorganic ions, can rationally be interpreted with a partition between the bulk liquid phase and the interfacial solvation liquid layer. The structural properties of the solvent layer on the C18-bonded layer determined by liquid chromatography are consistent with the molecular dynamics simulation results that have been obtained by other researchers.
Related Concept Videos
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
Thin-Layer Chromatography (TLC): Overview
To begin the analysis, a mixture of compounds is spotted on the starting line on the TLC plate using a thin capillary. The bottom of the...
Analyte Adsorption and Distribution
High-Performance Liquid Chromatography: Instrumentation
Chromatography: Introduction
The phase in which the compounds linger or on which the compounds adsorb is called the stationary phase, whereas the mobile phase is the solvent that carries the solutes to be analyzed. In traditional column chromatography, the mixture flows through the stationary phase, and the compounds partition between the stationary and mobile phases...
High-Performance Liquid Chromatography: Elution Process

