Related Experiment Video
Updated: Sep 23, 2025

Improved Registration of 3D CT Angiography with X-ray Fluoroscopy for Image Fusion During Transcatheter Aortic Valve Implantation
Published on: June 3, 2018
Artificial Intelligence-Based Spiral CT 3D Reconstruction in Transcatheter Aortic Valve Implantation
Kunpeng Zhang1, Yan Gao2, Junwei Lv2
1Department of Catheterization Room, The Affiliated Yantai Yuhuangding Hospital of Qingdao University, Yantai, 264000 Shandong, China.
Abstract:
To evaluate the clinical application effect of spiral computed tomography (CT) three-dimensional (3D) reconstruction based on artificial intelligence in transcatheter aortic valve implantation (TAVI), a CT 3D reconstruction model based on deep convolutional neural networks (DCNN) was established in this research, which was compared with the model-based iterative reconstruction (MBIR) and used in clinical practice. Then, 62 patients with aortic stenosis (AS) who underwent TAVI surgery were recruited as the research objects. The accuracy, sensitivity, and specificity of the multislice spiral CT scan (MSCT) and transthoracic echocardiography (TTE) in predicting the type of TAVI surgical valve were compared and analyzed. The results showed that the mean absolute error (MAE) (0.01) and root mean square error (RMSE) (0.086) of the MBIR model were higher than the reconstruction model in this research. The structural similarity (SSIM) (0.831) and peak signal-to noise ratio (PSNR) (32.77 dB) of the MBIR model were lower than the reconstruction model, and the differences were considerable (P < 0.05). Of the valve models selected based on the TTE measurement results, 35 cases were accurately predicted and 27 cases were incorrectly predicted. The accuracy of MSCT was 87.1%, the specificity was 98.84%, and the sensitivity was 92.87%; all of which were significantly higher than TTE (P < 0.05). In summary, compared with the MBIR reconstruction model, the imaging results of the model established in this research were closer to the real image. Compared with TTE, MSCT had higher accuracy, sensitivity, and specificity and can provide more accurate preoperative predictions for patients undergoing TAVI surgery.
More Related Videos
07:46Author Spotlight: Revolutionizing Remote Surgery with Augmented Reality and Robotics for Enhanced Precision and Accessibility
Published on: August 9, 2024
09:57Four-Dimensional Computed Tomography-Guided Valve Sizing for Transcatheter Pulmonary Valve Replacement
Published on: January 20, 2022