Related Experiment Video
Updated: Sep 23, 2025

A Novel Single Animal Motor Function Tracking System Using Simple, Readily Available Software
Published on: August 31, 2018
Comparison of six regression-based lot-to-lot verification approaches
Norman Wen Xuan Koh1, Corey Markus2, Tze Ping Loh3
1Engineering Cluster, Singapore Institute of Technology, Singapore, Singapore.
Objectives:
Detection of between-lot reagent bias is clinically important and can be assessed by application of regression-based statistics on several paired measurements obtained from the existing and new candidate lot. Here, the bias detection capability of six regression-based lot-to-lot reagent verification assessments, including an extension of the Bland-Altman with regression approach are compared.
Methods:
Least squares and Deming regression (in both weighted and unweighted forms), confidence ellipses and Bland-Altman with regression (BA-R) approaches were investigated. The numerical simulation included permutations of the following parameters: differing result range ratios (upper:lower measurement limits), levels of significance (alpha), constant and proportional biases, analytical coefficients of variation (CV), and numbers of replicates and sample sizes. The sample concentrations simulated were drawn from a uniformly distributed concentration range.
Results:
At a low range ratio (1:10, CV 3%), the BA-R performed the best, albeit with a higher false rejection rate and closely followed by weighted regression approaches. At larger range ratios (1:1,000, CV 3%), the BA-R performed poorly and weighted regression approaches performed the best. At higher assay imprecision (CV 10%), all six approaches performed poorly with bias detection rates <50%. A lower alpha reduced the false rejection rate, while greater sample numbers and replicates improved bias detection.
Conclusions:
When performing reagent lot verification, laboratories need to finely balance the false rejection rate (selecting an appropriate alpha) with the power of bias detection (appropriate statistical approach to match assay performance characteristics) and operational considerations (number of clinical samples and replicates, not having alternate reagent lot).
More Related Videos
Related Concept Videos
Data Validation
Key parameters for method validation include:
Residuals and Least-Squares Property
If the observed data point lies above the line, the residual is positive, and the line underestimates the actual data value for y. If the observed data point lies below the line, the residual is negative, and the line overestimates the actual data value for y.
The process of fitting the best-fit...
Multiple Regression
Farmers can use multiple regression to determine the crop yield based on more than one factor, such as water availability, fertilizer, soil properties, etc. Here, the crop yield is the response or dependent variable as it depends on the other independent variables. The analysis requires the construction of a scatter plot...
Multiple Comparison Tests
It would be easy to compare two samples using a significance alpha level of 0.05. In other words, there is only one sample pair to be compared. However, it would be difficult to identify a significantly different sample if the number...
One-Compartment Open Model: Wagner-Nelson and Loo Riegelman Method for ka Estimation
On...
Comparing Copy Number Variations and SNPs
Copy number variations or CNVs are the structural variations that cover more than 1kb of DNA sequence. The single nucleotide polymorphism (SNP), on the other hand, is a single nucleotide change or a point mutation that is found in more than 1%...