Online water sampling-quickMix-assisted miniscale liquid-liquid extraction coupled with full evaporation dynamic
Christina Shu Min Liew1, Hian Kee Lee2
1Integrative Sciences and Engineering Programme, NUS Graduate School, National University of Singapore, University Hall, Tan Chin Tuan Wing #04-02, 21 Lower Kent Ridge Road, Singapore 119077, Singapore; Department of Chemistry, National University of Singapore, 3 Science Drive 3, Singapore 117543, Singapore.
Abstract:
Polybrominated diphenyl ethers (PBDEs) are commonly used as flame retardants in daily household products and have been found to be detrimental to human and animal health. Being highly stable, accumulation can take place easily in the environment. In our previous studies, an innovative sample preparation method named miniscale liquid-liquid extraction (msLLE) coupled to full evaporation dynamic headspace (FEDHS) concentration was developed, and then successfully coupled to an online water sampling system, allowing full automation from water sampling to sample preparation, sample detection and analysis. In the present work, the fully automated online sampling-quickMix-assisted-msLLE-FEDHS platform was optimized and applied to PBDEs in environmental aqueous samples. The online sampling system was set up with a modified sample vial (to have an inlet and outlet), two tubings and a peristaltic pump which was programmed to control the water flow into and out of the vial. After adding 2 mL of the extractant (n-hexane), and 7 mL of sampled water to a 10-mL vial, msLLE was enabled, assisted with a quickMix module to ensure a quick and efficient mode of mixing between the organic and aqueous phases. The organic extract was then transferred to the FEDHS setup for selective trapping and concentration of the PBDEs, while the solvent was removed. The trap consisted of Tenax TA adsorbent, which has favorable π-interaction with the PBDEs but not with n-hexane. Subsequently, the adsorbent tube was automatically transported to the injector of the gas-chromatography mass-spectrometric (GC-MS) system to thermally desorb the trapped PBDEs for detection and analysis. The optimized methodology was found to achieve low limits of detection (0.0031 to 0.018 µg/L) with good linearity (r2 ≥ 0.9932) and satisfactory absolute extraction recoveries (between 61.4% and 80.9%). The analysis of PBDEs in spiked genuine water sample attained satisfactory and repeatable relative recoveries (between 106.1% and 132.6% with%RSDs ≤ 8.6%).
More Related Videos
04:39A Modified QuEChERS-HPLC Method for Detection of Polycyclic Aromatic Hydrocarbons in Zebrafish Embryos Exposed to Fine Particulate Matter
Published on: June 13, 2025
07:26A Simple Method for Automated Solid Phase Extraction of Water Samples for Immunological Analysis of Small Pollutants
Published on: January 1, 2016
