Cortical Bone Assessment Using Ultrasonic Guided Waves: A Reproducibility Study in a Healthy Population
Published on: January 31, 2025
Osteoporosis Diagnostic Model Using a Multichannel Convolutional Neural Network Based on Quantitative Ultrasound
Wenqiang Luo1, Zhiwei Chen2, Qi Zhang3
1Department of Orthopedic Surgery, Sun Yat-sen Memorial Hospital, Sun Yat-sen University, Guangzhou, China; Bioland Laboratory, Guangzhou, China.
Abstract:
Quantitative ultrasound (QUS) is a promising screening method for osteoporosis. In this study, a new method to improve the diagnostic accuracy of QUS was established in which a multichannel convolutional neural network (MCNN) processes the raw radiofrequency (RF) signal of QUS. The improvement in the diagnostic accuracy of osteoporosis using this new method was evaluated by comparison with the conventional speed of sound (SOS) method. Dual-energy X-ray absorptiometry was used as the diagnostic standard. After being trained, validated and tested in a data set consisting of 274 participants, the MCNN model could significantly raise the accuracy of osteoporosis diagnosis compared with the SOS method. The adjusted MCNN model performed even better when adjusted by age, height and weight data. The sensitivity, specificity and accuracy of the adjusted MCNN method for osteoporosis diagnosis were 80.86%, 84.23% and 83.05%, respectively; the corresponding values for SOS were 50.60%, 73.68% and 66.67%. The area under the receiver operating characteristic curve of the adjusted MCNN method was also higher than that of SOS (0.846 vs. 0.679). In conclusion, our study indicates that the MCNN method may be more accurate than the conventional SOS method. The MCNN tool and ultrasound RF signal analysis are promising future developmental directions for QUS in screening for osteoporosis.
More Related Videos
07:12Semiautomated Longitudinal Microcomputed Tomography-based Quantitative Structural Analysis of a Nude Rat Osteoporosis-related Vertebral Fracture Model
Published on: September 28, 2017
04:23A Swin Transformer-Based Model for Thyroid Nodule Detection in Ultrasound Images
Published on: April 21, 2023
Related Concept Videos
Ultrasonography
During an ultrasonography procedure, a handheld device called...
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Imaging Studies II: Ultrasonography
Ultrasound II: Endoscopic Ultrasound and FibroScan
Endoscopic Ultrasound (EUS):
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment: