A New Single Chamber Implantable Defibrillator with Atrial Sensing: A Practical Demonstration of Sensing and Ease of Implantation
Published on: February 28, 2012
High defibrillation threshold with right-sided ICD implantation was resolved by a dual coil lead via persistent left
Takefumi Fujito1, Daigo Nagahara1, Taro Tsuzuki1
1Department of Cardiovascular, Renal and Metabolic Medicine, Sapporo Medical University School of Medicine, Sapporo, Japan.
Abstract:
Persistent left superior vena cava (PLSVC) can be problematic when device implantation is scheduled from the left side because of the technical difficulty in delivering leads. Right-sided implantation is an alternative method, but there is a risk of a high defibrillation threshold (DFT). Transvenous implantation of an implantable cardioverter defibrillator (ICD) was scheduled for a 54-year-old man with idiopathic dilated cardiomyopathy and monomorphic non-sustained ventricular tachycardia, but computed tomography revealed the presence of a PLSVC. Right-sided ICD implantation was performed first; however, an ICD shock at 35 J failed to terminate the induced ventricular fibrillation (VF). Re-implantation via the PLSVC by a left subclavian approach with a dual coil lead was performed next. The dual coil right ventricular lead was successfully implanted via the PLSVC, and the induced VF was terminated by a single shock at 25 J. In the present case, the proximal coil was located in the coronary sinus (CS) and it enabled an antero-posterior defibrillation vector across the left ventricle. In addition to the re-location of the ICD generator from the right side to the left side, the new positioning of the proximal coil inside the CS is likely to have contributed to the great improvement of the DFT. <Learning objective: In cases with persistent left superior vena cava, left-sided implantationof an implantable cardioverter defibrillator (ICD) can be problematic because of the technical difficulty, but right-sided implantation has a risk of a high defibrillation threshold (DFT). Leftsided ICD via the persistent left superior vena cava with a dual coil lead enables an antero-posterior defibrillation vector across the left ventricle by positioning of the proximal coil inside the coronary sinus and contributes to a great improvement of the DFT.>.
More Related Videos
06:57Ablation of Ischemic Ventricular Tachycardia Using a Multipolar Catheter and 3-dimensional Mapping System for High-density Electro-anatomical Reconstruction
Published on: January 31, 2019
12:45Benefits of Cardiac Resynchronization Therapy in an Asynchronous Heart Failure Model Induced by Left Bundle Branch Ablation and Rapid Pacing
Published on: December 11, 2017
Related Concept Videos
Cardiac Catheterization II: Right Heart Catheterization
Cardiomyopathy V: Interprofessional Care