Related Experiment Video
Updated: Sep 22, 2025

10:17
Laser-induced Breakdown Spectroscopy: A New Approach for Nanoparticle's Mapping and Quantification in Organ Tissue
Published on: June 18, 2014
13.9K
Insertable, Scabbarded, and Nanoetched Silver Needle Sensor for Hazardous Element Depth Profiling by Laser-Induced
Yuanchao Liu1, Binbin Zhou2,3,4, Weiliang Wang5
1Department of Physics, City University of Hong Kong, Kowloon, Hong Kong SAR 999077, China.
ACS Sensors
|May 18, 2022
Summary
A novel nanoetched silver needle sensor offers rapid hazardous heavy metal detection and depth profiling. This insertable, scabbarded sensor provides accurate elemental analysis for challenging samples like meat and soil.
Area of Science:
- Analytical Chemistry
- Materials Science
- Environmental Science
Background:
- Hazardous heavy metal contamination poses significant risks to public health and the environment.
- Laser-induced breakdown spectroscopy (LIBS) is a powerful tool for elemental analysis but struggles with complex sample matrices.
- Direct analysis of loose, water-containing, or bulk samples using LIBS is challenging, limiting its application in areas like food safety and environmental monitoring.
Purpose of the Study:
- To develop a novel sensor for rapid hazardous heavy metal sensing and depth profiling.
- To overcome the limitations of traditional LIBS analysis for challenging sample types.
- To enable accurate elemental depth profiling in bulk samples.
Main Methods:
- Development of an insertable, scabbarded, and nanoetched silver (NE-Ag) needle sensor.
- Utilizing a micro-nanostructure surface for analyte absorption and a stainless-steel scabbard for protection.
- Application of the sensor for Laser-induced breakdown spectroscopy (LIBS) analysis of hazardous elements.
Main Results:
- The NE-Ag needle sensor demonstrated high sensitivity for cadmium (Cd) detection with a limit of detection of 0.8 mg/L and a relative standard deviation of 6.7%.
- Excellent correlation (Pearson correlation coefficient ≥ 0.96) was achieved for Cd and chromium (Cr) depth profiling.
- The entire testing process, including sample preparation and analysis, could be completed in under 1 hour.
Conclusions:
- The insertable and scabbarded NE-Ag needle sensor is a promising tool for rapid hazardous heavy metal sensing and depth profiling.
- This innovative sensor overcomes key limitations of LIBS, enabling analysis of difficult sample matrices.
- The technology holds significant potential for applications in environmental monitoring, food safety, and industrial quality control.