An improved calibrated mass spectrometry for absolute copper isotope-ratio measurement using two strategies for mass
Panshu Song1, Tao Zhou1, Jun Wang1
1Division of Chemical Metrology and Analytical Science, National Institute of Metrology, Beijing, 100029, PR China.
Abstract:
Modern advances in multi-collector inductively coupled plasma mass spectrometry (MC-ICPMS) have greatly promoted the investigation of copper isotopes in various research fields. To meet the demand, an improved calibrated mass spectrometry for the absolute determination of copper isotopic composition was developed in this study. The method has made progress in the investigation of instrumental mass bias correction factor for copper isotopic analysis using MC-ICPMS through employing two independent strategies. One is the conventional mathematical iterative method based on the MC-ICPMS measurement data; the other one is direct calculation using the absolute copper isotopic compositions in isotopically enriched 63Cu and 65Cu materials by developing a TE-TIMS method. The results of Kiter = 0.95563(16)k = 1 and KTE = 0.95551(17)k = 1 were consistent in their standard uncertainties, demonstrated the first cross-validation of these two strategies. Thereafter, the proposed calibrated mass spectrometry were applied to re-measure the copper isotope amount ratios in three isotopic reference materials, resulted in RNIST SRM 97665/63 = 0.44547(16)k = 2, RERM®-AE63365/63 = 0.44549(16)k = 2, and RERM®-AE64765/63 = 0.44557(16)k = 2, respectively. These expended uncertainties were only one third or one fifth of the stated uncertainties in their certificates. Furthermore, the absolute copper isotopic compositions in four natural-abundance samples and a new copper isotopic reference material GBW04624 were determined, given an average atomic weight of copper as Ar(Cu) = 63.5456(4)k = 2. The δ65Cu values of GBW04624 relative to NIST SRM 976, ERM®-AE633 and ERM®-AE647 were also applied by implementing the C-SSBIN calibration model. This provides an additional independently certified and SI-traceable copper isotopic reference material, in support of various scientific researches.
Related Concept Videos
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences
Mass Spectrometry: Isotope Effect
High-Resolution Mass Spectrometry (HRMS)
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview
Atomic Absorption Spectroscopy: Lab
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing...
Atomic Absorption Spectroscopy: Interference
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...