Estimation of the mid-upper arm circumference measurement error.

C W Bishop, S J Pitchey

    Journal of the American Dietetic Association
    |April 1, 1987
    PubMed
    Summary

    Mid-upper arm circumference (MUAC) measurement error was assessed to detect small patient changes during hospitalization. Different observers introduce more error, but consistent measurements by the same observer can detect changes as small as 2.2%.

    Related Concept Videos

    You might also read

    Related Articles

    Articles linked to this work by shared authors, journal, and citation graph.

    Sort by
    Same author

    Prostate cancer prevention strategies using antiproliferative or differentiating agents.

    Urology·2001
    Same author

    Efficacy and side effects of intermittent intravenous and oral doxercalciferol (1alpha-hydroxyvitamin D(2)) in dialysis patients with secondary hyperparathyroidism: a sequential comparison.

    American journal of kidney diseases : the official journal of the National Kidney Foundation·2001
    Same author

    Intermittent doxercalciferol (1alpha-hydroxyvitamin D(2)) therapy for secondary hyperparathyroidism.

    American journal of kidney diseases : the official journal of the National Kidney Foundation·2000
    Same author

    Unique 24-hydroxylated metabolites represent a significant pathway of metabolism of vitamin D2 in humans: 24-hydroxyvitamin D2 and 1,24-dihydroxyvitamin D2 detectable in human serum.

    The Journal of clinical endocrinology and metabolism·1998
    Same author

    Pharmacokinetics and systemic effect on calcium homeostasis of 1 alpha,24-dihydroxyvitamin D2 in rats. Comparison with 1 alpha,25-dihydroxyvitamin D2, calcitriol, and calcipotriol.

    Biochemical pharmacology·1997
    Same author

    Effective suppression of parathyroid hormone by 1 alpha-hydroxy-vitamin D2 in hemodialysis patients with moderate to severe secondary hyperparathyroidism.

    Kidney international·1997

    Area of Science:

    • Clinical Measurement
    • Anthropometry
    • Patient Monitoring

    Background:

    • Accurate measurement of mid-upper arm circumference (MUAC) is crucial for assessing nutritional status and detecting changes during hospitalization.
    • Understanding measurement error is key to interpreting MUAC data effectively.

    Purpose of the Study:

    • To estimate the measurement error associated with mid-upper arm circumference (MUAC).
    • To evaluate the usefulness of MUAC for detecting small changes in patients during hospitalization.

    Main Methods:

    • A 3x3x2 factorial design study involving 10 trained observers and 52 healthy adult subjects.
    • 1,560 MUAC measurements were recorded, with each observer taking three independent measurements per subject.
    • Analysis of variance was used to estimate measurement variation between observers and between repeated measurements by the same observer.

    Main Results:

    • Variation between different observers' MUAC measurements was ≤2.8% for men and ≤3.8% for women.
    • Variation between repeated measurements by the same observer was ≤1.1% and unaffected by subject factors.
    • The smallest detectable change in MUAC was 7.8% (men) and 9.8% (women) with different observers, but only 2.2% with the same observer.

    Conclusions:

    • MUAC measurement error is influenced by observer variability.
    • Consistent measurement by the same observer significantly reduces detectable change thresholds.
    • MUAC can reliably detect small changes when measurements are standardized to a single observer.