Related Experiment Video
Updated: Sep 22, 2025

Fiber Optic Distributed Sensors for High-resolution Temperature Field Mapping
Published on: November 7, 2016
Extension of Duplexed Single-Ended Distributed Temperature Sensing Calibration Algorithms and Their Application in
Matías Lillo1,2,3, Francisco Suárez1,2,3, Mark B Hausner4
1Departamento de Ingeniería Hidráulica y Ambiental, Pontificia Universidad Católica de Chile, Santiago 7820436, Chile.
Abstract:
Fiber-optic distributed temperature sensing (DTS) has been widely used since the end of the 20th century, with various industrial, Earth sciences, and research applications. To obtain precise thermal measurements, it is important to extend the currently available DTS calibration methods, considering that environmental and deployment factors can strongly impact these measurements. In this work, a laboratory experiment was performed to assess a currently available duplexed single-ended DTS calibration algorithm and to extend it in case no temperature information is available at the end of the cables, which is extremely important in geothermal applications. The extended calibration algorithms were tested in different boreholes located in the Atacama Desert and in the Central Andes Mountains to estimate the geothermal gradient in these regions. The best algorithm found achieved a root mean square error of 0.31 ± 0.07 °C at the far end of a ~1.1-km cable, which is much smaller than that obtained using the manufacturer algorithm (2.17 ± 0.35 °C). Moreover, temperature differences between single- and double-ended measurements were less than 0.3 °C at the far end of the cable, which results in differences of ~0.5 °C km-1 when determining the geothermal gradient. This improvement in the geothermal gradient is relevant, as it can reduce the drilling depth by at least 700 m in the study area. Future work should investigate new extensions of the algorithms for other DTS configurations and determining the flow rate of the Central Andes Mountains artesian well using the geothermal profile provided by the DTS measurements and the available data of the borehole.
More Related Videos
08:49Manufacturing Simple and Inexpensive Soil Surface Temperature and Gravimetric Water Content Sensors
Published on: December 21, 2019
10:52Design, Instrumentation and Usage Protocols for Distributed In Situ Thermal Hot Spots Monitoring in Electric Coils using FBG Sensor Multiplexing
Published on: March 8, 2020
Related Concept Videos
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Distance Corrections
Thermometers and Temperature Scales
As many physical properties depend on temperature, the variety of thermometers is...
Gas Thermometers and the Kelvin Scale
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...