Single-Phase Grounding Fault Types Identification Based on Multi-Feature Transformation and Fusion
Min Fan1, Jialu Xia1, Xinyu Meng1
1College of Automation, Chongqing University, Chongqing 400044, China.
Abstract:
The frequent occurrence of single-phase grounding faults affects the reliable operation of power systems. When a single-phase grounding fault occurs, it is difficult to accurately identify the fault type because of the weak characterization and subtle distinction between different fault types. Therefore, this paper proposes a single-phase grounding fault type identification method based on the multi-feature transformation and fusion. Firstly, the Hilbert-Huang transform (HHT) was used to preprocess the fault recorded wave data to highlight the characteristics between different fault types. Secondly, the deep learning model ResNet18 and the long short-term memory (LSTM) are designed to extract the complex abstract features and time-series correlation features from the preprocessed data set separately. Finally, it designs a fusion model to combine the advantages of heterogeneous models to identify the type of single-phase grounding fault. Experiments validate that the method is good at fully mining the characteristics of the fault types contained in the fault recorded wave data, so it can identify multiple types of faults with strong robustness and provide a reliable basis for the subsequent formulation of targeted fault-handling measures.
More Related Videos
06:45Design and Application of a Fault Detection Method Based on Adaptive Filters and Rotational Speed Estimation for an Electro-Hydrostatic Actuator
Published on: October 28, 2022
13:44Detection of Architectural Distortion in Prior Mammograms via Analysis of Oriented Patterns
Published on: August 30, 2013
Related Concept Videos
Fault Types
For line-to-line faults occurring between phases B and C, the...
Power System Three-Phase Short Circuits
Three-Phase Short Circuit—Unloaded Synchronous Machine
This behavior occurs due to the magnetic flux produced by the short-circuit armature currents. Initially, these currents follow high-reluctance paths but eventually shift to...
Bus Impedance Matrix
In the first circuit, all machine voltage sources are short-circuited, leaving only the prefault voltage source at the fault location. The positive-sequence bus impedance matrix can be determined by solving the nodal equations,...
Line Protection with Impedance Relays
Under normal conditions, low load currents keep the measured...
Reducing Line Loss
With a step-up transformer at the source, the voltage is increased, thereby reducing the current in the transmission lines since power loss...