Izaz Ahmad1, Mudasir Iqbal1,2, Asim Abbas1
1Department of Civil Engineering, University of Engineering & Technology, Peshawar 25120, Pakistan.
Abstract:
Steel fibers are widely extracted from scrap tyres, causing environmental concerns. This paper presents the use of steel fibers in variable proportions extracted from scrap tyres. The enhancement of the confinement was envisaged through the addition of steel fibers obtained from scrap tyres. The study included an experimental program for the development of constitutive material models for ordinary Portland cement (OPC) concrete and concrete with added steel fibers. A mix design was carried out for OPC, targeting a compressive strength of 3000 psi. Steel fibers were added to OPC in ratios of 1.0% to 3.0%, with an increment of 0.5%. Concrete columns, with cross-sectional dimensions of 6 × 6 inches and a length of 30 inches, were cast with both OPC and fiber-reinforced concrete. The column confinement was evaluated with a different spacing of ties (3- and 4-inch center-to-center). Compression tests on the concrete columns indicate that the addition of steel fibers to a concrete matrix results in an appreciable increase in strength and ductility. Overall, increasing the percentage of steel fibers increased the compression strength and the ductility of concrete. The maximum strain in the concrete containing 2.5% steel fibers increased by 285% as compared to the concrete containing 1% of steel fibers. An optimum percentage of 2.5% steel fibers added to the concrete resulted in a 39% increase in compressive strength, accompanied by a significant improvement in ductility. The optimum content of steel fibers, when used in confined columns, showed that confined compression strength increased with the addition of steel fibers. However, it is recommended that additional columns on the basis of the optimum steel fiber content shall be tested to evaluate their effectiveness in reducing the stirrup spacing.
Related Concept Videos
Reinforcements in Concrete
Fiber Reinforced Concrete
Tensile Strength Considerations of Concrete
The dimensions and shape of a concrete specimen...
Design Example: Distributing Reinforcements in Concrete Sections
Corrosion of Reinforcement
However, over time and under certain conditions like carbonation, chloride ingress, and cracking this protective state can be compromised. Steel has areas with...
Effects of Creep