Related Experiment Video
Updated: Sep 22, 2025

Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition
Published on: March 11, 2021
Is Dose Volume a Better Predictor of Osteoradionecrosis Risk Than Total Dose for Patients Who Have Received Head and
Dean DeLuke1, Caroline Carrico2, Christopher Ray3
1Professor Emeritus, Department of Oral and Maxillofacial Surgery, Virginia Commonwealth University and VCU Medical Center, Richmond, VA.
Purpose:
Oral and maxillofacial surgeons frequently encounter patients who require extractions following exposure to head and neck radiation, and they must assess the risk of extraction and consider alternatives such as deliberate root retention. The purpose of this study was to determine whether dose volume would be a better predictor for osteoradionecrosis (ORN) than total dose.
Methods:
This is a retrospective cohort study of patients diagnosed with ORN following head and neck radiation (administered between January 2006 and December 2018) and a comparison group selected based on site and dosage who did not develop ORN. The predictor variables were total radiation dose and mandibular dose volume, and the outcome variable was ORN occurrence. Covariates included age, sex, cancer stage and site, radiation therapy type, smoking status, alcohol use, adjuvant chemotherapy use, medical comorbidities, and concomitant tumor surgery. Logistic regression models were employed and area under receiver operating characteristic curve (AUROC) and model accuracy (Acc) were used to determine the better predictor.
Results:
A total of 56 patients were included in the study: 27 ORN positive (ORN+) and 29 matched controls who did not develop ORN (ORN-). Most patients were male (76.8%), considered smokers (78.6%), used alcohol (80.4%), were in stage IV (66.1%), received chemotherapy (75.0%), and received intensity modulated radiation therapy radiation (55.4%). The statistical models with V50 Gy (cc) and V65 Gy (cc) dosage variables exhibited greater predictability of ORN occurrence than total dose (AUROC: 0.90 vs 0.76 and model accuracy: 0.82 vs 0.75, respectively).
Conclusions:
The results suggest that following head and neck radiation, dose volume may be a better predictor of ORN risk than total dose. This finding is significant, both for the oral and maxillofacial surgeon who is preoperatively assessing ORN risk following radiation exposure, and for the radiation oncologist striving to minimize the risk associated with their treatment.
More Related Videos
07:57Positron Emission Tomography-based Dose Painting Radiation Therapy in a Glioblastoma Rat Model using the Small Animal Radiation Research Platform
Published on: March 24, 2022
08:34Proton Therapy Delivery and Its Clinical Application in Select Solid Tumor Malignancies
Published on: February 6, 2019
Related Concept Videos
Renal Failure: Dose Adjustments
Reduced renal clearance and elimination rate are common outcomes of renal impairment. These alterations lead to a prolonged elimination half-life and an altered apparent volume of distribution for drugs. As a result, dosage adjustments are typically necessary to maintain optimal drug levels in the body.
However, dosage adjustments...
Biological Effects of Radiation
Dose-Response Relationship: Overview
Dose-Response Relationship: Potency and Efficacy
Dosage Regimen: Fixed Dose
Fixed-dose regimens can be used for various routes of administration, including intravenous (IV) injections and oral medications. For IV administration, a predetermined amount of the drug is...
Rational Dosage Regimen: Maintenance Dose and Loading Dose
In most cases, drugs are administered repetitively or infused continuously to maintain a steady-state concentration in the body. At a steady...