Related Experiment Video
Updated: Sep 22, 2025

Interphase Fluorescence in situ Hybridization of Bone Marrow Smears of Multiple Myeloma
Published on: April 15, 2022
Defects and countermeasures in laboratory diagnosis of rare IgE multiple myeloma
Yongjian Chen1, Yuzhou Chen2, Yanping Zhou3
1Laboratory Medicine Center, Department of Clinical Laboratory, Zhejiang Provincial People's Hospital (Affiliated People's Hospital, Hangzhou Medical College), Hangzhou, Zhejiang 310014, China.
Background:
IgE multiple myeloma (MM) is a rare subtype of MM that is easily misdiagnosed. We report a rare case of IgE-MM and investigate the application of the SLiM-CRAB criteria to screen for high-risk smoldering MM (SMM) patients, so as to summarize the causes and methods used to prevent missed diagnosis or misdiagnosis in IgE-MM.
Methods:
The serum monoclonal protein (M-protein) classification and IgE quantification was performed and sent to several individual institutions. The results were collected and the causes of IgE detection defects were analyzed.
Results:
Upon admission to our hospital, the patient's serum free kappa light chain was 1069.9 mg/L, free lambda light chain was 9.2 mg/L, and free kappa/lambda ratio was 115.9, which met the SLiM criteria, but without CRAB features. Immunofixation electrophoresis (IF) showed "M-like protein aggregation bands" in all lanes. After pretreatment with 1% β-mercaptoethanol to depolymerize the aggregation of monoclonal protein, the "M-like protein aggregation bands disappeared. The other five institutions did not provide the correct typing results. The quantification of serum IgE was as high as 2.06 × 107 IU/mL, whereas 7 other testing institutions reported IgE levels ranging from 1.0 to 1100 IU/mL.
Conclusion:
High-risk biomarkers in SLiM criteria can achieve good therapeutic effects in rare IgE-MM patients. Serum immunofixation performed without antisera against IgE, insufficient identification of the lytic bands produced by high macromolecule aggregation in IF, and the absence of a prozone effect avoidance procedure during IgE quantitative detection are the primary causes of missed diagnosis or misdiagnosis in patients with IgE-MM.
More Related Videos
09:25Detection and Enrichment of Rare Antigen-specific B Cells for Analysis of Phenotype and Function
Published on: February 16, 2017
09:57Comprehensive Protocol to Sample and Process Bone Marrow for Measuring Measurable Residual Disease and Leukemic Stem Cells in Acute Myeloid Leukemia
Published on: March 5, 2018