Related Experiment Video
Updated: Sep 22, 2025

Evaluating the Effect of Roadside Parking on a Dual-Direction Urban Street
Published on: January 20, 2023
Particulate matter exposure at urban traffic intersection during haze episodes: A case study in Changsha
Wei Pan1, Xiaolu Chen2, Xiaojun Duan3
1College of Liberal Arts and Science, National University of Defense Technology, Changsha, Hunan 410073, PR China; School of Basic Medical Sciences, Guangxi Medical University, Nanning 530021, PR China; School of Information and Management, Guangxi Medical University, Nanning 530021, PR China.
Abstract:
Urban intersection has been identified as a major contributor to the total personal exposure and short-term high exposure of particulate matter (PM) in modern cities. The main aim of this study was to get a better understanding of the determinants of traffic-related PM temporal variations and personal exposure to PMs at a viaduct-covered intersection controlled by traffic signals during the winter haze episodes. A two-day field sampling campaign was conducted with a portable device during evening rush hour and measured the PMs in the 0.3-10 μm size range both on the surface crosswalk and underground passage. PM variations and related cumulative respiratory deposition dose (RDD) along two routes with six road crossing scenarios were estimated on a severe pollution day and a typical day for both adults and children, respectively. The PM concentration on the severe pollution day ranged 59.2-67.9 μg/m3 for PM1, 163.8-257.0 μg/m3 for PM2, and 258.2-469.1 μg/m3 for PM10, respectively, as compared to 47.9-57.9 μg/m3for PM1, 112.7-199.8 μg/m3 for PM2, and 151.0-301.0 μg/m3 for PM10 on the typical day, respectively. The variability could be explained largely by the built-up environment, traffic component, signal setting, and ventilation condition. Our data suggest that an appropriate setting of the traffic signal would help reduce the personal exposure dose on the surface crosswalk at urban intersections and the ventilation condition had a significant influence on local PM distributions inside the underground passage. Results here provide possible suggestions for the future design of a walkable city.
More Related Videos
05:18Measuring Carbon Content in Airway Macrophages Exposed to Carbon-Containing Particulate Matters
Published on: July 12, 2024
09:33Visualizing Field Data Collection Procedures of Exposure and Biomarker Assessments for the Household Air Pollution Intervention Network Trial in India
Published on: December 23, 2022