Application of Heterocyclic Polymers in the Ratiometric Spectrophotometric Determination of Fluoride

Jinming Hu1, Michael R Whittaker1, Thomas P Davis1,2

  • 1ARC Centre of Excellence in Convergent Bio-Nano Science and Technology, Monash Institute of Pharmaceutical Sciences, Monash University, Parkville, VIC 3052, Australia.

ACS Macro Letters
|May 21, 2022
PubMed

Related Concept Videos

Photoluminescence: Applications01:14

Photoluminescence: Applications

Photoluminescence offers a wide range of applications due to its inherent sensitivity and selectivity. This technique allows for both direct and indirect analyses of the analyte. Direct quantitative analysis is possible when the analyte exhibits a favorable quantum yield for fluorescence or phosphorescence. However, an indirect analysis may be feasible if the analyte is not fluorescent or phosphorescent, or if the quantum yield is unfavorable. Indirect methods include reacting the analyte with...
509
Fluorescence and Phosphorescence: Instrumentation01:25

Fluorescence and Phosphorescence: Instrumentation

Fluorometers and spectrofluorometers are two types of instruments used for measuring molecular fluorescence. These instruments differ in how they select excitation and emission wavelengths and the type of light sources they utilize. Fluorometers use absorption interference filters to choose excitation and emission wavelengths. The excitation source in a fluorometer is typically a low-pressure mercury vapor lamp that emits intense lines distributed throughout the ultraviolet and visible regions.
784
Electrophilic Aromatic Substitution: Fluorination and Iodination of Benzene01:13

Electrophilic Aromatic Substitution: Fluorination and Iodination of Benzene

Bromination and chlorination of aromatic rings by electrophilic aromatic substitution reactions are easily achieved, but fluorination and iodination are difficult to achieve. Fluorine is so reactive that its reaction with benzene is difficult to control, resulting in poor yields of monofluoroaromatic products. To address this, Selectfluor reagent is used as a fluorine source in which a fluorine atom is bonded to a positively charged nitrogen.
6.5K
Gas Chromatography: Types of Detectors-II01:19

Gas Chromatography: Types of Detectors-II

In gas chromatography, different detectors are employed to meet specific analytical needs. These detectors are often categorized based on their detection mechanisms and the types of compounds they are best suited to analyze. Thermal Conductivity Detectors (TCD), Flame Ionization Detectors (FID), and Electron Capture Detectors (ECD) represent common categories, each with unique operating principles and applications. However, beyond these, several other detectors are designed for more specialized...
529
Complexometric Titration: Ligands00:43

Complexometric Titration: Ligands

Different monodentate and polydentate ligands are used as complexing agents in complexometric titration reactions. The formation of complexes by mono- and bidentate ligands involves two or more intermediate steps, limiting their use as complexing agents. In comparison, polydentate ligands can form complexes with metal ions in a single-step process, facilitating sharper end points. This means polydentate ligands, such as amino carboxylic acid derivatives, are most commonly employed in...
1.1K
Flame Photometry: Lab01:16

Flame Photometry: Lab

In a flame photometer, when a solution like potassium chloride is aspirated into the flame, the solvent evaporates, leaving behind dehydrated salt. This salt dissociates into free gaseous atoms in their ground state. Some of these atoms absorb energy from the flame, leading to their excitation. The excited atoms return to the ground state, emitting photons at characteristic wavelengths. Because only electronic transitions are involved, the resulting emission lines are very narrow. The intensity...
393